Qualified pluggable modules directory
SmartNIC compatibility for qualified/supported pluggable modules.
Click on the Columns eye icon to see more technical data.
Filter Data
SmartNIC | Link Speed Gbit/s | Form Factor | Link Type | Napatech Order No. | Manufacturer | Manufacturer Part No. | EOL | Supported from Capture driver version | Power Class rating (1) | Opr. Temp (°C) rating | WAN Support rating | Latch function | Network Connection | Cable Length | Wire Size | EEPROM User Data | Temperature monitoring | Volt monitoring | Rx Power monitoring | Tx Power monitoring | Tx On/Off control | Regulatory Safety Approved with Products |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
NT4E | 1G | SFP | BASE-T | N/A | FIT | HBCU-5710R | No | "1.0.0" | II | 0 to 70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | Yes |
NT4E2 | 1G | SFP | BASE-T | N/A | FIT | HBCU-5710R | No | "1.0.0" | II | 0 to 70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | Yes |
NT40A01 | 1G | SFP | BASE-T | N/A | FIT | HBCU-5710R | No | "1.0.0" | II | 0 to 70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | Yes |
NT20E3 | 1G | SFP | BASE-T | N/A | FIT | HBCU-5710R | No | "1.0.0" | II | 0 to 70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | Yes |
NT40E3 | 1G | SFP | BASE-T | N/A | FIT | HBCU-5710R | No | "1.0.0" | II | 0 to 70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | Yes |
NT40A11 | 1G | SFP | BASE-T | N/A | FIT | HBCU-5710R | No | "1.0.0" | II | 0 to 70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | Yes |
NT100A01 | 1G | SFP | BASE-T | N/A | FIT | HBCU-5710R | No | "1.0.0" | II | 0 to 70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | Yes |
NT200A02 | 1G | SFP | BASE-T | N/A | FIT | HBCU-5710R | No | "1.0.0" | II | 0 to 70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | Yes |
NT4E | 1G | SFP | BASE-T | N/A | FIT | ABCU-5710RZ | No | "1.0.0" | II | 0 to 70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | Yes |
NT4E2 | 1G | SFP | BASE-T | N/A | FIT | ABCU-5710RZ | No | "1.0.0" | II | 0 to 70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | Yes |
NT40A01 | 1G | SFP | BASE-T | N/A | FIT | ABCU-5710RZ | No | "1.0.0" | II | 0 to 70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | Yes |
NT20E3 | 1G | SFP | BASE-T | N/A | FIT | ABCU-5710RZ | No | "1.0.0" | II | 0 to 70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | Yes |
NT40E3 | 1G | SFP | BASE-T | N/A | FIT | ABCU-5710RZ | No | "1.0.0" | II | 0 to 70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | Yes |
NT40A11 | 1G | SFP | BASE-T | N/A | FIT | ABCU-5710RZ | No | "1.0.0" | II | 0 to 70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | Yes |
NT100A01 | 1G | SFP | BASE-T | N/A | FIT | ABCU-5710RZ | No | "1.0.0" | II | 0 to 70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | Yes |
NT200A02 | 1G | SFP | BASE-T | N/A | FIT | ABCU-5710RZ | No | "1.0.0" | II | 0 to 70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | Yes |
NT4E | 1G | SFP | BASE-T | N/A | AMC Optics | GLC-TE | No | "1.0.0" | II | 0 to 70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT4E2 | 1G | SFP | BASE-T | N/A | AMC Optics | GLC-TE | No | "1.0.0" | II | 0 to 70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT40A01 | 1G | SFP | BASE-T | N/A | AMC Optics | GLC-TE | No | "1.0.0" | II | 0 to 70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT20E3 | 1G | SFP | BASE-T | N/A | AMC Optics | GLC-TE | No | "1.0.0" | II | 0 to 70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT40E3 | 1G | SFP | BASE-T | N/A | AMC Optics | GLC-TE | No | "1.0.0" | II | 0 to 70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT40A11 | 1G | SFP | BASE-T | N/A | AMC Optics | GLC-TE | No | "1.0.0" | II | 0 to 70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT100A01 | 1G | SFP | BASE-T | N/A | AMC Optics | GLC-TE | No | "1.0.0" | II | 0 to 70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT200A02 | 1G | SFP | BASE-T | N/A | AMC Optics | GLC-TE | No | "1.0.0" | II | 0 to 70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT4E | 100/1000M | SFP | BASE-T | N/A | AOC Technologies | AMXP-24RJS | No | "3.0.1" | II | 0 to70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT4E2 | 100/1000M | SFP | BASE-T | N/A | AOC Technologies | AMXP-24RJS | No | "3.0.1" | II | 0 to70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT40A01 | 100/1000M | SFP | BASE-T | N/A | AOC Technologies | AMXP-24RJS | No | "3.0.1" | II | 0 to70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT20E3 | 100/1000M | SFP | BASE-T | N/A | AOC Technologies | AMXP-24RJS | No | "3.0.1" | II | 0 to70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT40E3 | 100/1000M | SFP | BASE-T | N/A | AOC Technologies | AMXP-24RJS | No | "3.0.1" | II | 0 to70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT40A11 | 100/1000M | SFP | BASE-T | N/A | AOC Technologies | AMXP-24RJS | No | "3.0.1" | II | 0 to70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT100A01 | 100/1000M | SFP | BASE-T | N/A | AOC Technologies | AMXP-24RJS | No | "3.0.1" | II | 0 to70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT200A02 | 100/1000M | SFP | BASE-T | N/A | AOC Technologies | AMXP-24RJS | No | "3.0.1" | II | 0 to70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT4E | 100/1000M | SFP | BASE-T | N/A | FIT | ABCU-5740RZ | No | "3.0.1" | II | 0 to70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT4E2 | 100/1000M | SFP | BASE-T | N/A | FIT | ABCU-5740RZ | No | "3.0.1" | II | 0 to70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT40A01 | 100/1000M | SFP | BASE-T | N/A | FIT | ABCU-5740RZ | No | "3.0.1" | II | 0 to70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT20E3 | 100/1000M | SFP | BASE-T | N/A | FIT | ABCU-5740RZ | No | "3.0.1" | II | 0 to70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT40E3 | 100/1000M | SFP | BASE-T | N/A | FIT | ABCU-5740RZ | No | "3.0.1" | II | 0 to70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT40A11 | 100/1000M | SFP | BASE-T | N/A | FIT | ABCU-5740RZ | No | "3.0.1" | II | 0 to70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT100A01 | 100/1000M | SFP | BASE-T | N/A | FIT | ABCU-5740RZ | No | "3.0.1" | II | 0 to70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT200A02 | 100/1000M | SFP | BASE-T | N/A | FIT | ABCU-5740RZ | No | "3.0.1" | II | 0 to70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT4E | 100/1000M | SFP | BASE-T | N/A | Eoptolink | EOLT-C12-02A | No | "3.0.1" | II | 0 to70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT4E2 | 100/1000M | SFP | BASE-T | N/A | Eoptolink | EOLT-C12-02A | No | "3.0.1" | II | 0 to70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT40A01 | 100/1000M | SFP | BASE-T | N/A | Eoptolink | EOLT-C12-02A | No | "3.0.1" | II | 0 to70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT20E3 | 100/1000M | SFP | BASE-T | N/A | Eoptolink | EOLT-C12-02A | No | "3.0.1" | II | 0 to70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT40E3 | 100/1000M | SFP | BASE-T | N/A | Eoptolink | EOLT-C12-02A | No | "3.0.1" | II | 0 to70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT40A11 | 100/1000M | SFP | BASE-T | N/A | Eoptolink | EOLT-C12-02A | No | "3.0.1" | II | 0 to70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT100A01 | 100/1000M | SFP | BASE-T | N/A | Eoptolink | EOLT-C12-02A | No | "3.0.1" | II | 0 to70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT200A02 | 100/1000M | SFP | BASE-T | N/A | Eoptolink | EOLT-C12-02A | No | "3.0.1" | II | 0 to70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT4E | 100/1000M | SFP | BASE-T | 802-0025-00-01 | Finisar | FCLF-8521-3 | Yes | "3.0.1" | II | 0 to 85 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | Yes |
NT4E2 | 100/1000M | SFP | BASE-T | 802-0025-00-01 | Finisar | FCLF-8521-3 | Yes | "3.0.1" | II | 0 to 85 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | Yes |
NT40A01 | 100/1000M | SFP | BASE-T | 802-0025-00-01 | Finisar | FCLF-8521-3 | Yes | "3.0.1" | II | 0 to 85 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | Yes |
NT20E3 | 100/1000M | SFP | BASE-T | 802-0025-00-01 | Finisar | FCLF-8521-3 | Yes | "3.0.1" | II | 0 to 85 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | Yes |
NT40E3 | 100/1000M | SFP | BASE-T | 802-0025-00-01 | Finisar | FCLF-8521-3 | Yes | "3.0.1" | II | 0 to 85 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | Yes |
NT40A11 | 100/1000M | SFP | BASE-T | 802-0025-00-01 | Finisar | FCLF-8521-3 | Yes | "3.0.1" | II | 0 to 85 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | Yes |
NT100A01 | 100/1000M | SFP | BASE-T | 802-0025-00-01 | Finisar | FCLF-8521-3 | Yes | "3.0.1" | II | 0 to 85 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | Yes |
NT200A02 | 100/1000M | SFP | BASE-T | 802-0025-00-01 | Finisar | FCLF-8521-3 | Yes | "3.0.1" | II | 0 to 85 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | Yes |
NT4E | 100/1000M | SFP | BASE-T | 802-0025-00-01 | Finisar | FCLF8521P2BTL | No | "3.0.1" | II | 0 to 85 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | Yes |
NT4E2 | 100/1000M | SFP | BASE-T | 802-0025-00-01 | Finisar | FCLF8521P2BTL | No | "3.0.1" | II | 0 to 85 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | Yes |
NT40A01 | 100/1000M | SFP | BASE-T | 802-0025-00-01 | Finisar | FCLF8521P2BTL | No | "3.0.1" | II | 0 to 85 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | Yes |
NT20E3 | 100/1000M | SFP | BASE-T | 802-0025-00-01 | Finisar | FCLF8521P2BTL | No | "3.0.1" | II | 0 to 85 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | Yes |
NT40E3 | 100/1000M | SFP | BASE-T | 802-0025-00-01 | Finisar | FCLF8521P2BTL | No | "3.0.1" | II | 0 to 85 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | Yes |
NT40A11 | 100/1000M | SFP | BASE-T | 802-0025-00-01 | Finisar | FCLF8521P2BTL | No | "3.0.1" | II | 0 to 85 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | Yes |
NT100A01 | 100/1000M | SFP | BASE-T | 802-0025-00-01 | Finisar | FCLF8521P2BTL | No | "3.0.1" | II | 0 to 85 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | Yes |
NT200A02 | 100/1000M | SFP | BASE-T | 802-0025-00-01 | Finisar | FCLF8521P2BTL | No | "3.0.1" | II | 0 to 85 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | Yes |
NT4E | 1G | SFP | BASE-SX | N/A | FIT | AFBR-57L5APZ | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT4E2 | 1G | SFP | BASE-SX | N/A | FIT | AFBR-57L5APZ | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40A01 | 1G | SFP | BASE-SX | N/A | FIT | AFBR-57L5APZ | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT20E3 | 1G | SFP | BASE-SX | N/A | FIT | AFBR-57L5APZ | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40E3 | 1G | SFP | BASE-SX | N/A | FIT | AFBR-57L5APZ | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40A11 | 1G | SFP | BASE-SX | N/A | FIT | AFBR-57L5APZ | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT100A01 | 1G | SFP | BASE-SX | N/A | FIT | AFBR-57L5APZ | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 1G | SFP | BASE-SX | N/A | FIT | AFBR-57L5APZ | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT4E | 1G | SFP | BASE-SX | N/A | FIT | AFBR-5715PZ | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | No |
NT4E2 | 1G | SFP | BASE-SX | N/A | FIT | AFBR-5715PZ | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | No |
NT40A01 | 1G | SFP | BASE-SX | N/A | FIT | AFBR-5715PZ | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | No |
NT20E3 | 1G | SFP | BASE-SX | N/A | FIT | AFBR-5715PZ | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | No |
NT40E3 | 1G | SFP | BASE-SX | N/A | FIT | AFBR-5715PZ | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | No |
NT40A11 | 1G | SFP | BASE-SX | N/A | FIT | AFBR-5715PZ | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | No |
NT100A01 | 1G | SFP | BASE-SX | N/A | FIT | AFBR-5715PZ | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 1G | SFP | BASE-SX | N/A | FIT | AFBR-5715PZ | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | No |
NT4E | 1G | SFP | BASE-SX | 802-0002-00-01 | Lumentum | PLRXPL-VI-S24-22 | Yes | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT4E2 | 1G | SFP | BASE-SX | 802-0002-00-01 | Lumentum | PLRXPL-VI-S24-22 | Yes | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A01 | 1G | SFP | BASE-SX | 802-0002-00-01 | Lumentum | PLRXPL-VI-S24-22 | Yes | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E3 | 1G | SFP | BASE-SX | 802-0002-00-01 | Lumentum | PLRXPL-VI-S24-22 | Yes | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E3 | 1G | SFP | BASE-SX | 802-0002-00-01 | Lumentum | PLRXPL-VI-S24-22 | Yes | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A11 | 1G | SFP | BASE-SX | 802-0002-00-01 | Lumentum | PLRXPL-VI-S24-22 | Yes | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 1G | SFP | BASE-SX | 802-0002-00-01 | Lumentum | PLRXPL-VI-S24-22 | Yes | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 1G | SFP | BASE-SX | 802-0002-00-01 | Lumentum | PLRXPL-VI-S24-22 | Yes | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT4E | 1G | SFP | BASE-SX | 802-0002-00-01 | Finisar | FTLF8519P3BNL | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT4E2 | 1G | SFP | BASE-SX | 802-0002-00-01 | Finisar | FTLF8519P3BNL | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40A01 | 1G | SFP | BASE-SX | 802-0002-00-01 | Finisar | FTLF8519P3BNL | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT20E3 | 1G | SFP | BASE-SX | 802-0002-00-01 | Finisar | FTLF8519P3BNL | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40E3 | 1G | SFP | BASE-SX | 802-0002-00-01 | Finisar | FTLF8519P3BNL | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40A11 | 1G | SFP | BASE-SX | 802-0002-00-01 | Finisar | FTLF8519P3BNL | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT100A01 | 1G | SFP | BASE-SX | 802-0002-00-01 | Finisar | FTLF8519P3BNL | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 1G | SFP | BASE-SX | 802-0002-00-01 | Finisar | FTLF8519P3BNL | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT4E | 1G | SFP | BASE-SX | N/A | AMC Optics | GLC-SX-MMD | No | "1.0.0" | I | 0 to 70 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT4E2 | 1G | SFP | BASE-SX | N/A | AMC Optics | GLC-SX-MMD | No | "1.0.0" | I | 0 to 70 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40A01 | 1G | SFP | BASE-SX | N/A | AMC Optics | GLC-SX-MMD | No | "1.0.0" | I | 0 to 70 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT20E3 | 1G | SFP | BASE-SX | N/A | AMC Optics | GLC-SX-MMD | No | "1.0.0" | I | 0 to 70 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40E3 | 1G | SFP | BASE-SX | N/A | AMC Optics | GLC-SX-MMD | No | "1.0.0" | I | 0 to 70 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40A11 | 1G | SFP | BASE-SX | N/A | AMC Optics | GLC-SX-MMD | No | "1.0.0" | I | 0 to 70 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT100A01 | 1G | SFP | BASE-SX | N/A | AMC Optics | GLC-SX-MMD | No | "1.0.0" | I | 0 to 70 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 1G | SFP | BASE-SX | N/A | AMC Optics | GLC-SX-MMD | No | "1.0.0" | I | 0 to 70 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT4E | 1G | SFP | BASE-SX | N/A | Finisar | FTLF8524P3BNL | No | "1.0.0" | I | -40 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT4E2 | 1G | SFP | BASE-SX | N/A | Finisar | FTLF8524P3BNL | No | "1.0.0" | I | -40 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40A01 | 1G | SFP | BASE-SX | N/A | Finisar | FTLF8524P3BNL | No | "1.0.0" | I | -40 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT20E3 | 1G | SFP | BASE-SX | N/A | Finisar | FTLF8524P3BNL | No | "1.0.0" | I | -40 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40E3 | 1G | SFP | BASE-SX | N/A | Finisar | FTLF8524P3BNL | No | "1.0.0" | I | -40 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40A11 | 1G | SFP | BASE-SX | N/A | Finisar | FTLF8524P3BNL | No | "1.0.0" | I | -40 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT100A01 | 1G | SFP | BASE-SX | N/A | Finisar | FTLF8524P3BNL | No | "1.0.0" | I | -40 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 1G | SFP | BASE-SX | N/A | Finisar | FTLF8524P3BNL | No | "1.0.0" | I | -40 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT4E | 1G | SFP | BASE-LX | N/A | FIT | AFCT-5715PZ | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | Yes |
NT4E2 | 1G | SFP | BASE-LX | N/A | FIT | AFCT-5715PZ | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A01 | 1G | SFP | BASE-LX | N/A | FIT | AFCT-5715PZ | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E3 | 1G | SFP | BASE-LX | N/A | FIT | AFCT-5715PZ | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E3 | 1G | SFP | BASE-LX | N/A | FIT | AFCT-5715PZ | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A11 | 1G | SFP | BASE-LX | N/A | FIT | AFCT-5715PZ | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 1G | SFP | BASE-LX | N/A | FIT | AFCT-5715PZ | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 1G | SFP | BASE-LX | N/A | FIT | AFCT-5715PZ | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | Yes |
NT4E | 1G | SFP | BASE-LX | N/A | Finisar | FTLF1319P1BTL | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | P/W | Yes | Yes | Yes | Yes | Yes | No |
NT4E2 | 1G | SFP | BASE-LX | N/A | Finisar | FTLF1319P1BTL | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | P/W | Yes | Yes | Yes | Yes | Yes | No |
NT40A01 | 1G | SFP | BASE-LX | N/A | Finisar | FTLF1319P1BTL | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | P/W | Yes | Yes | Yes | Yes | Yes | No |
NT20E3 | 1G | SFP | BASE-LX | N/A | Finisar | FTLF1319P1BTL | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | P/W | Yes | Yes | Yes | Yes | Yes | No |
NT40E3 | 1G | SFP | BASE-LX | N/A | Finisar | FTLF1319P1BTL | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | P/W | Yes | Yes | Yes | Yes | Yes | No |
NT40A11 | 1G | SFP | BASE-LX | N/A | Finisar | FTLF1319P1BTL | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | P/W | Yes | Yes | Yes | Yes | Yes | No |
NT100A01 | 1G | SFP | BASE-LX | N/A | Finisar | FTLF1319P1BTL | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | P/W | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 1G | SFP | BASE-LX | N/A | Finisar | FTLF1319P1BTL | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | P/W | Yes | Yes | Yes | Yes | Yes | No |
NT4E | 1G | SFP | BASE-LX | 802-0003-00-01 | Finisar | FTLF1318P2BTL | Yes | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | P/W | Yes | Yes | Yes | Yes | Yes | Yes |
NT4E2 | 1G | SFP | BASE-LX | 802-0003-00-01 | Finisar | FTLF1318P2BTL | Yes | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | P/W | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A01 | 1G | SFP | BASE-LX | 802-0003-00-01 | Finisar | FTLF1318P2BTL | Yes | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | P/W | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E3 | 1G | SFP | BASE-LX | 802-0003-00-01 | Finisar | FTLF1318P2BTL | Yes | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | P/W | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E3 | 1G | SFP | BASE-LX | 802-0003-00-01 | Finisar | FTLF1318P2BTL | Yes | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | P/W | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A11 | 1G | SFP | BASE-LX | 802-0003-00-01 | Finisar | FTLF1318P2BTL | Yes | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | P/W | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 1G | SFP | BASE-LX | 802-0003-00-01 | Finisar | FTLF1318P2BTL | Yes | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | P/W | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 1G | SFP | BASE-LX | 802-0003-00-01 | Finisar | FTLF1318P2BTL | Yes | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | P/W | Yes | Yes | Yes | Yes | Yes | Yes |
NT4E | 1G | SFP | BASE-LX | N/A | Finisar | FTLF1318P3BTL | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | P/W | Yes | Yes | Yes | Yes | Yes | No |
NT4E2 | 1G | SFP | BASE-LX | N/A | Finisar | FTLF1318P3BTL | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | P/W | Yes | Yes | Yes | Yes | Yes | No |
NT40A01 | 1G | SFP | BASE-LX | N/A | Finisar | FTLF1318P3BTL | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | P/W | Yes | Yes | Yes | Yes | Yes | No |
NT20E3 | 1G | SFP | BASE-LX | N/A | Finisar | FTLF1318P3BTL | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | P/W | Yes | Yes | Yes | Yes | Yes | No |
NT40E3 | 1G | SFP | BASE-LX | N/A | Finisar | FTLF1318P3BTL | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | P/W | Yes | Yes | Yes | Yes | Yes | No |
NT40A11 | 1G | SFP | BASE-LX | N/A | Finisar | FTLF1318P3BTL | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | P/W | Yes | Yes | Yes | Yes | Yes | No |
NT100A01 | 1G | SFP | BASE-LX | N/A | Finisar | FTLF1318P3BTL | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | P/W | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 1G | SFP | BASE-LX | N/A | Finisar | FTLF1318P3BTL | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | P/W | Yes | Yes | Yes | Yes | Yes | No |
NT4E | 1G | SFP | BASE-LX | N/A | Sumitomo | SCP6G44-GL-AWH | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT4E2 | 1G | SFP | BASE-LX | N/A | Sumitomo | SCP6G44-GL-AWH | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A01 | 1G | SFP | BASE-LX | N/A | Sumitomo | SCP6G44-GL-AWH | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E3 | 1G | SFP | BASE-LX | N/A | Sumitomo | SCP6G44-GL-AWH | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E3 | 1G | SFP | BASE-LX | N/A | Sumitomo | SCP6G44-GL-AWH | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A11 | 1G | SFP | BASE-LX | N/A | Sumitomo | SCP6G44-GL-AWH | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 1G | SFP | BASE-LX | N/A | Sumitomo | SCP6G44-GL-AWH | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 1G | SFP | BASE-LX | N/A | Sumitomo | SCP6G44-GL-AWH | No | "1.0.0" | I | 0 to 85 | N/A | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT4E | 1G | SFP | BASE-ZX | N/A | Finisar | FTLF1619P1BCL | No | "1.0.0" | I | 0 to 70 | N/A | Bail | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | No | No |
NT4E2 | 1G | SFP | BASE-ZX | N/A | Finisar | FTLF1619P1BCL | No | "1.0.0" | I | 0 to 70 | N/A | Bail | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | No | No |
NT40A01 | 1G | SFP | BASE-ZX | N/A | Finisar | FTLF1619P1BCL | No | "1.0.0" | I | 0 to 70 | N/A | Bail | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | No | No |
NT20E3 | 1G | SFP | BASE-ZX | N/A | Finisar | FTLF1619P1BCL | No | "1.0.0" | I | 0 to 70 | N/A | Bail | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | No | No |
NT40E3 | 1G | SFP | BASE-ZX | N/A | Finisar | FTLF1619P1BCL | No | "1.0.0" | I | 0 to 70 | N/A | Bail | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | No | No |
NT40A11 | 1G | SFP | BASE-ZX | N/A | Finisar | FTLF1619P1BCL | No | "1.0.0" | I | 0 to 70 | N/A | Bail | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | No | No |
NT100A01 | 1G | SFP | BASE-ZX | N/A | Finisar | FTLF1619P1BCL | No | "1.0.0" | I | 0 to 70 | N/A | Bail | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | No | No |
NT200A02 | 1G | SFP | BASE-ZX | N/A | Finisar | FTLF1619P1BCL | No | "1.0.0" | I | 0 to 70 | N/A | Bail | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | No | No |
NT20E2 | 10G | SFP+ | BASE-T | N/A | ModuleTek | SFP10-T-C-D15 | No | "3.27.0" | II | 0 to 70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT40E2-4 | 10G | SFP+ | BASE-T | N/A | ModuleTek | SFP10-T-C-D15 | No | "3.27.0" | II | 0 to 70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT20E3 | 10G | SFP+ | BASE-T | N/A | ModuleTek | SFP10-T-C-D15 | No | "3.27.0" | II | 0 to 70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT40E3 | 10G | SFP+ | BASE-T | N/A | ModuleTek | SFP10-T-C-D15 | No | "3.27.0" | II | 0 to 70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT40A11 | 10G | SFP+ | BASE-T | N/A | ModuleTek | SFP10-T-C-D15 | No | "3.27.0" | II | 0 to 70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT50B01 | 10G | SFP+ | BASE-T | N/A | ModuleTek | SFP10-T-C-D15 | No | "3.27.0" | II | 0 to 70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT100A01 | 10G | SFP+ | BASE-T | N/A | ModuleTek | SFP10-T-C-D15 | No | "3.27.0" | II | 0 to 70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT200A02 | 10G | SFP+ | BASE-T | N/A | ModuleTek | SFP10-T-C-D15 | No | "3.27.0" | II | 0 to 70 | N/A | Bail | RJ45 | N/A | N/A | No | No | No | N/A | N/A | N/A | No |
NT20E2 | 10G | SFP+ | BASE-SR | N/A | FIT | AFBR-703SDZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-4 | 10G | SFP+ | BASE-SR | N/A | FIT | AFBR-703SDZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E3 | 10G | SFP+ | BASE-SR | N/A | FIT | AFBR-703SDZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E3 | 10G | SFP+ | BASE-SR | N/A | FIT | AFBR-703SDZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A11 | 10G | SFP+ | BASE-SR | N/A | FIT | AFBR-703SDZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT50B01 | 10G | SFP+ | BASE-SR | N/A | FIT | AFBR-703SDZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 10G | SFP+ | BASE-SR | N/A | FIT | AFBR-703SDZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 10G | SFP+ | BASE-SR | N/A | FIT | AFBR-703SDZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E2 | 10G | SFP+ | BASE-SR | N/A | FIT | AFBR-703SDDZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-4 | 10G | SFP+ | BASE-SR | N/A | FIT | AFBR-703SDDZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E3 | 10G | SFP+ | BASE-SR | N/A | FIT | AFBR-703SDDZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E3 | 10G | SFP+ | BASE-SR | N/A | FIT | AFBR-703SDDZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A11 | 10G | SFP+ | BASE-SR | N/A | FIT | AFBR-703SDDZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT50B01 | 10G | SFP+ | BASE-SR | N/A | FIT | AFBR-703SDDZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 10G | SFP+ | BASE-SR | N/A | FIT | AFBR-703SDDZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 10G | SFP+ | BASE-SR | N/A | FIT | AFBR-703SDDZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E2 | 10G | SFP+ | BASE-SR | N/A | FIT | AFBR-709SMZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-4 | 10G | SFP+ | BASE-SR | N/A | FIT | AFBR-709SMZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E3 | 10G | SFP+ | BASE-SR | N/A | FIT | AFBR-709SMZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E3 | 10G | SFP+ | BASE-SR | N/A | FIT | AFBR-709SMZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A11 | 10G | SFP+ | BASE-SR | N/A | FIT | AFBR-709SMZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT50B01 | 10G | SFP+ | BASE-SR | N/A | FIT | AFBR-709SMZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 10G | SFP+ | BASE-SR | N/A | FIT | AFBR-709SMZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 10G | SFP+ | BASE-SR | N/A | FIT | AFBR-709SMZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E2 | 10G | SFP+ | BASE-SR | N/A | CoreTek | CT-A000NPP-SB1L-D | No | "1.0.0" | uk | uk | uk | Bail | LC | N/A | N/A | No | Yes | uk | Yes | uk | Yes | No |
NT40E2-4 | 10G | SFP+ | BASE-SR | N/A | CoreTek | CT-A000NPP-SB1L-D | No | "1.0.0" | uk | uk | uk | Bail | LC | N/A | N/A | No | Yes | uk | Yes | uk | Yes | No |
NT20E3 | 10G | SFP+ | BASE-SR | N/A | CoreTek | CT-A000NPP-SB1L-D | No | "1.0.0" | uk | uk | uk | Bail | LC | N/A | N/A | No | Yes | uk | Yes | uk | Yes | No |
NT40E3 | 10G | SFP+ | BASE-SR | N/A | CoreTek | CT-A000NPP-SB1L-D | No | "1.0.0" | uk | uk | uk | Bail | LC | N/A | N/A | No | Yes | uk | Yes | uk | Yes | No |
NT40A11 | 10G | SFP+ | BASE-SR | N/A | CoreTek | CT-A000NPP-SB1L-D | No | "1.0.0" | uk | uk | uk | Bail | LC | N/A | N/A | No | Yes | uk | Yes | uk | Yes | No |
NT50B01 | 10G | SFP+ | BASE-SR | N/A | CoreTek | CT-A000NPP-SB1L-D | No | "1.0.0" | uk | uk | uk | Bail | LC | N/A | N/A | No | Yes | uk | Yes | uk | Yes | No |
NT100A01 | 10G | SFP+ | BASE-SR | N/A | CoreTek | CT-A000NPP-SB1L-D | No | "1.0.0" | uk | uk | uk | Bail | LC | N/A | N/A | No | Yes | uk | Yes | uk | Yes | No |
NT200A02 | 10G | SFP+ | BASE-SR | N/A | CoreTek | CT-A000NPP-SB1L-D | No | "1.0.0" | uk | uk | uk | Bail | LC | N/A | N/A | No | Yes | uk | Yes | uk | Yes | No |
NT20E2 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Finisar | FTLX8571D3BCL | Yes | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-4 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Finisar | FTLX8571D3BCL | Yes | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E3 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Finisar | FTLX8571D3BCL | Yes | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E3 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Finisar | FTLX8571D3BCL | Yes | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A11 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Finisar | FTLX8571D3BCL | Yes | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT50B01 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Finisar | FTLX8571D3BCL | Yes | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Finisar | FTLX8571D3BCL | Yes | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Finisar | FTLX8571D3BCL | Yes | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E2 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Finisar | FTLX8574D3BCL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-4 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Finisar | FTLX8574D3BCL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E3 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Finisar | FTLX8574D3BCL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E3 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Finisar | FTLX8574D3BCL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A11 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Finisar | FTLX8574D3BCL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT50B01 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Finisar | FTLX8574D3BCL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Finisar | FTLX8574D3BCL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Finisar | FTLX8574D3BCL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E2 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Finisar | FTLX8571D3BCV | Yes | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-4 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Finisar | FTLX8571D3BCV | Yes | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E3 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Finisar | FTLX8571D3BCV | Yes | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E3 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Finisar | FTLX8571D3BCV | Yes | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A11 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Finisar | FTLX8571D3BCV | Yes | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT50B01 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Finisar | FTLX8571D3BCV | Yes | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Finisar | FTLX8571D3BCV | Yes | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Finisar | FTLX8571D3BCV | Yes | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E2 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Finisar | FTLX8574D3BCV | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-4 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Finisar | FTLX8574D3BCV | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E3 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Finisar | FTLX8574D3BCV | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E3 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Finisar | FTLX8574D3BCV | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A11 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Finisar | FTLX8574D3BCV | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT50B01 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Finisar | FTLX8574D3BCV | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Finisar | FTLX8574D3BCV | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Finisar | FTLX8574D3BCV | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E2 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Lumentum | PLRXPL-SC-S43-22-N | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-4 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Lumentum | PLRXPL-SC-S43-22-N | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E3 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Lumentum | PLRXPL-SC-S43-22-N | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E3 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Lumentum | PLRXPL-SC-S43-22-N | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A11 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Lumentum | PLRXPL-SC-S43-22-N | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT50B01 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Lumentum | PLRXPL-SC-S43-22-N | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Lumentum | PLRXPL-SC-S43-22-N | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Lumentum | PLRXPL-SC-S43-22-N | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E2 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Lumentum | PLRXPL-VC-S43-23-N | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-4 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Lumentum | PLRXPL-VC-S43-23-N | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E3 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Lumentum | PLRXPL-VC-S43-23-N | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E3 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Lumentum | PLRXPL-VC-S43-23-N | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A11 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Lumentum | PLRXPL-VC-S43-23-N | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT50B01 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Lumentum | PLRXPL-VC-S43-23-N | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Lumentum | PLRXPL-VC-S43-23-N | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 10G | SFP+ | BASE-SR | 802-0038-01-01 | Lumentum | PLRXPL-VC-S43-23-N | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E2 | 10G | SFP+ | BASE-SR | N/A | Sumitomo | SPP5100SR-GL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-4 | 10G | SFP+ | BASE-SR | N/A | Sumitomo | SPP5100SR-GL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E3 | 10G | SFP+ | BASE-SR | N/A | Sumitomo | SPP5100SR-GL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E3 | 10G | SFP+ | BASE-SR | N/A | Sumitomo | SPP5100SR-GL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A11 | 10G | SFP+ | BASE-SR | N/A | Sumitomo | SPP5100SR-GL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT50B01 | 10G | SFP+ | BASE-SR | N/A | Sumitomo | SPP5100SR-GL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 10G | SFP+ | BASE-SR | N/A | Sumitomo | SPP5100SR-GL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 10G | SFP+ | BASE-SR | N/A | Sumitomo | SPP5100SR-GL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E2 | 10G | SFP+ | BASE-SR | N/A | Cisco | 10-2415-02 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40E2-4 | 10G | SFP+ | BASE-SR | N/A | Cisco | 10-2415-02 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT20E3 | 10G | SFP+ | BASE-SR | N/A | Cisco | 10-2415-02 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40E3 | 10G | SFP+ | BASE-SR | N/A | Cisco | 10-2415-02 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40A11 | 10G | SFP+ | BASE-SR | N/A | Cisco | 10-2415-02 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT50B01 | 10G | SFP+ | BASE-SR | N/A | Cisco | 10-2415-02 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT100A01 | 10G | SFP+ | BASE-SR | N/A | Cisco | 10-2415-02 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 10G | SFP+ | BASE-SR | N/A | Cisco | 10-2415-02 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT20E2 | 10G | SFP+ | BASE-SR | N/A | Innolight | TR-PX85S-NRS | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40E2-4 | 10G | SFP+ | BASE-SR | N/A | Innolight | TR-PX85S-NRS | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT20E3 | 10G | SFP+ | BASE-SR | N/A | Innolight | TR-PX85S-NRS | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40E3 | 10G | SFP+ | BASE-SR | N/A | Innolight | TR-PX85S-NRS | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40A11 | 10G | SFP+ | BASE-SR | N/A | Innolight | TR-PX85S-NRS | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT50B01 | 10G | SFP+ | BASE-SR | N/A | Innolight | TR-PX85S-NRS | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT100A01 | 10G | SFP+ | BASE-SR | N/A | Innolight | TR-PX85S-NRS | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 10G | SFP+ | BASE-SR | N/A | Innolight | TR-PX85S-NRS | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT20E2 | 10G | SFP+ | BASE-SR | N/A | Flexoptix | P.8596.02 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40E2-4 | 10G | SFP+ | BASE-SR | N/A | Flexoptix | P.8596.02 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT20E3 | 10G | SFP+ | BASE-SR | N/A | Flexoptix | P.8596.02 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40E3 | 10G | SFP+ | BASE-SR | N/A | Flexoptix | P.8596.02 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40A11 | 10G | SFP+ | BASE-SR | N/A | Flexoptix | P.8596.02 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT50B01 | 10G | SFP+ | BASE-SR | N/A | Flexoptix | P.8596.02 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT100A01 | 10G | SFP+ | BASE-SR | N/A | Flexoptix | P.8596.02 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 10G | SFP+ | BASE-SR | N/A | Flexoptix | P.8596.02 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT20E2 | 10G | SFP+ | BASE-SR | N/A | AMC Optics | iSFP-10G-SR | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40E2-4 | 10G | SFP+ | BASE-SR | N/A | AMC Optics | iSFP-10G-SR | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT20E3 | 10G | SFP+ | BASE-SR | N/A | AMC Optics | iSFP-10G-SR | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40E3 | 10G | SFP+ | BASE-SR | N/A | AMC Optics | iSFP-10G-SR | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40A11 | 10G | SFP+ | BASE-SR | N/A | AMC Optics | iSFP-10G-SR | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT50B01 | 10G | SFP+ | BASE-SR | N/A | AMC Optics | iSFP-10G-SR | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT100A01 | 10G | SFP+ | BASE-SR | N/A | AMC Optics | iSFP-10G-SR | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 10G | SFP+ | BASE-SR | N/A | AMC Optics | iSFP-10G-SR | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT4E | 1/10G | SFP+ | BASE-SR | 802-0078-01-10 | FIT | AFBR-709DMZ | Yes | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT4E2 | 1/10G | SFP+ | BASE-SR | 802-0078-01-10 | FIT | AFBR-709DMZ | Yes | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A01 | 1/10G | SFP+ | BASE-SR | 802-0078-01-10 | FIT | AFBR-709DMZ | Yes | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E2 | 1/10G | SFP+ | BASE-SR | 802-0078-01-10 | FIT | AFBR-709DMZ | Yes | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-4 | 1/10G | SFP+ | BASE-SR | 802-0078-01-10 | FIT | AFBR-709DMZ | Yes | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E3 | 1/10G | SFP+ | BASE-SR | 802-0078-01-10 | FIT | AFBR-709DMZ | Yes | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E3 | 1/10G | SFP+ | BASE-SR | 802-0078-01-10 | FIT | AFBR-709DMZ | Yes | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A11 | 1/10G | SFP+ | BASE-SR | 802-0078-01-10 | FIT | AFBR-709DMZ | Yes | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT50B01 | 1/10G | SFP+ | BASE-SR | 802-0078-01-10 | FIT | AFBR-709DMZ | Yes | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 1/10G | SFP+ | BASE-SR | 802-0078-01-10 | FIT | AFBR-709DMZ | Yes | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 1/10G | SFP+ | BASE-SR | 802-0078-01-10 | FIT | AFBR-709DMZ | Yes | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT4E | 1/10G | SFP+ | BASE-SR | 802-0078-01-10 | Finisar | FTLX8571D3BCV | Yes | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT4E2 | 1/10G | SFP+ | BASE-SR | 802-0078-01-10 | Finisar | FTLX8571D3BCV | Yes | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A01 | 1/10G | SFP+ | BASE-SR | 802-0078-01-10 | Finisar | FTLX8571D3BCV | Yes | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E2 | 1/10G | SFP+ | BASE-SR | 802-0078-01-10 | Finisar | FTLX8571D3BCV | Yes | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-4 | 1/10G | SFP+ | BASE-SR | 802-0078-01-10 | Finisar | FTLX8571D3BCV | Yes | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E3 | 1/10G | SFP+ | BASE-SR | 802-0078-01-10 | Finisar | FTLX8571D3BCV | Yes | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E3 | 1/10G | SFP+ | BASE-SR | 802-0078-01-10 | Finisar | FTLX8571D3BCV | Yes | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A11 | 1/10G | SFP+ | BASE-SR | 802-0078-01-10 | Finisar | FTLX8571D3BCV | Yes | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT50B01 | 1/10G | SFP+ | BASE-SR | 802-0078-01-10 | Finisar | FTLX8571D3BCV | Yes | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 1/10G | SFP+ | BASE-SR | 802-0078-01-10 | Finisar | FTLX8571D3BCV | Yes | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 1/10G | SFP+ | BASE-SR | 802-0078-01-10 | Finisar | FTLX8571D3BCV | Yes | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT4E | 1/10G | SFP+ | BASE-SR | 802-0078-01-10 | Finisar | FTLX8574D3BCV | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT4E2 | 1/10G | SFP+ | BASE-SR | 802-0078-01-10 | Finisar | FTLX8574D3BCV | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A01 | 1/10G | SFP+ | BASE-SR | 802-0078-01-10 | Finisar | FTLX8574D3BCV | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E2 | 1/10G | SFP+ | BASE-SR | 802-0078-01-10 | Finisar | FTLX8574D3BCV | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-4 | 1/10G | SFP+ | BASE-SR | 802-0078-01-10 | Finisar | FTLX8574D3BCV | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E3 | 1/10G | SFP+ | BASE-SR | 802-0078-01-10 | Finisar | FTLX8574D3BCV | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E3 | 1/10G | SFP+ | BASE-SR | 802-0078-01-10 | Finisar | FTLX8574D3BCV | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A11 | 1/10G | SFP+ | BASE-SR | 802-0078-01-10 | Finisar | FTLX8574D3BCV | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT50B01 | 1/10G | SFP+ | BASE-SR | 802-0078-01-10 | Finisar | FTLX8574D3BCV | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 1/10G | SFP+ | BASE-SR | 802-0078-01-10 | Finisar | FTLX8574D3BCV | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 1/10G | SFP+ | BASE-SR | 802-0078-01-10 | Finisar | FTLX8574D3BCV | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E2 | 10G | SFP+ | BASE-LR | N/A | FIT | AFCT-701SDDZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-4 | 10G | SFP+ | BASE-LR | N/A | FIT | AFCT-701SDDZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E3 | 10G | SFP+ | BASE-LR | N/A | FIT | AFCT-701SDDZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E3 | 10G | SFP+ | BASE-LR | N/A | FIT | AFCT-701SDDZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A11 | 10G | SFP+ | BASE-LR | N/A | FIT | AFCT-701SDDZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT50B01 | 10G | SFP+ | BASE-LR | N/A | FIT | AFCT-701SDDZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 10G | SFP+ | BASE-LR | N/A | FIT | AFCT-701SDDZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 10G | SFP+ | BASE-LR | N/A | FIT | AFCT-701SDDZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E2 | 10G | SFP+ | BASE-LR | N/A | FIT | AFCT-701SDZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-4 | 10G | SFP+ | BASE-LR | N/A | FIT | AFCT-701SDZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E3 | 10G | SFP+ | BASE-LR | N/A | FIT | AFCT-701SDZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E3 | 10G | SFP+ | BASE-LR | N/A | FIT | AFCT-701SDZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A11 | 10G | SFP+ | BASE-LR | N/A | FIT | AFCT-701SDZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT50B01 | 10G | SFP+ | BASE-LR | N/A | FIT | AFCT-701SDZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 10G | SFP+ | BASE-LR | N/A | FIT | AFCT-701SDZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 10G | SFP+ | BASE-LR | N/A | FIT | AFCT-701SDZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E2 | 10G | SFP+ | BASE-LR | N/A | FIT | AFCT-739SMZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | No |
NT40E2-4 | 10G | SFP+ | BASE-LR | N/A | FIT | AFCT-739SMZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | No |
NT20E3 | 10G | SFP+ | BASE-LR | N/A | FIT | AFCT-739SMZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | No |
NT40E3 | 10G | SFP+ | BASE-LR | N/A | FIT | AFCT-739SMZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | No |
NT40A11 | 10G | SFP+ | BASE-LR | N/A | FIT | AFCT-739SMZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | No |
NT50B01 | 10G | SFP+ | BASE-LR | N/A | FIT | AFCT-739SMZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | No |
NT100A01 | 10G | SFP+ | BASE-LR | N/A | FIT | AFCT-739SMZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 10G | SFP+ | BASE-LR | N/A | FIT | AFCT-739SMZ | No | "1.0.0" | I | 0 to 70 | No | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | No |
NT20E2 | 10G | SFP+ | BASE-LR | N/A | CoreTek | CT-A000TPP-NB4L-D | No | "1.0.0" | uk | uk | uk | Bail | LC | N/A | N/A | No | Yes | uk | Yes | uk | Yes | No |
NT40E2-4 | 10G | SFP+ | BASE-LR | N/A | CoreTek | CT-A000TPP-NB4L-D | No | "1.0.0" | uk | uk | uk | Bail | LC | N/A | N/A | No | Yes | uk | Yes | uk | Yes | No |
NT20E3 | 10G | SFP+ | BASE-LR | N/A | CoreTek | CT-A000TPP-NB4L-D | No | "1.0.0" | uk | uk | uk | Bail | LC | N/A | N/A | No | Yes | uk | Yes | uk | Yes | No |
NT40E3 | 10G | SFP+ | BASE-LR | N/A | CoreTek | CT-A000TPP-NB4L-D | No | "1.0.0" | uk | uk | uk | Bail | LC | N/A | N/A | No | Yes | uk | Yes | uk | Yes | No |
NT40A11 | 10G | SFP+ | BASE-LR | N/A | CoreTek | CT-A000TPP-NB4L-D | No | "1.0.0" | uk | uk | uk | Bail | LC | N/A | N/A | No | Yes | uk | Yes | uk | Yes | No |
NT50B01 | 10G | SFP+ | BASE-LR | N/A | CoreTek | CT-A000TPP-NB4L-D | No | "1.0.0" | uk | uk | uk | Bail | LC | N/A | N/A | No | Yes | uk | Yes | uk | Yes | No |
NT100A01 | 10G | SFP+ | BASE-LR | N/A | CoreTek | CT-A000TPP-NB4L-D | No | "1.0.0" | uk | uk | uk | Bail | LC | N/A | N/A | No | Yes | uk | Yes | uk | Yes | No |
NT200A02 | 10G | SFP+ | BASE-LR | N/A | CoreTek | CT-A000TPP-NB4L-D | No | "1.0.0" | uk | uk | uk | Bail | LC | N/A | N/A | No | Yes | uk | Yes | uk | Yes | No |
NT20E2 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | FIT | AFCT-739DMZ | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-4 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | FIT | AFCT-739DMZ | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E3 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | FIT | AFCT-739DMZ | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E3 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | FIT | AFCT-739DMZ | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A11 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | FIT | AFCT-739DMZ | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT50B01 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | FIT | AFCT-739DMZ | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | FIT | AFCT-739DMZ | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | FIT | AFCT-739DMZ | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E2 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | Finisar | FTLX1471D3BCL | Yes | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-4 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | Finisar | FTLX1471D3BCL | Yes | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E3 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | Finisar | FTLX1471D3BCL | Yes | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E3 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | Finisar | FTLX1471D3BCL | Yes | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A11 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | Finisar | FTLX1471D3BCL | Yes | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT50B01 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | Finisar | FTLX1471D3BCL | Yes | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | Finisar | FTLX1471D3BCL | Yes | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | Finisar | FTLX1471D3BCL | Yes | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E2 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | Finisar | FTLX1471D3BCV | Yes | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-4 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | Finisar | FTLX1471D3BCV | Yes | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E3 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | Finisar | FTLX1471D3BCV | Yes | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E3 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | Finisar | FTLX1471D3BCV | Yes | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A11 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | Finisar | FTLX1471D3BCV | Yes | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT50B01 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | Finisar | FTLX1471D3BCV | Yes | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | Finisar | FTLX1471D3BCV | Yes | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | Finisar | FTLX1471D3BCV | Yes | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E2 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | Finisar | FTLX1475D3BCL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-4 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | Finisar | FTLX1475D3BCL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E3 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | Finisar | FTLX1475D3BCL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E3 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | Finisar | FTLX1475D3BCL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A11 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | Finisar | FTLX1475D3BCL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT50B01 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | Finisar | FTLX1475D3BCL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | Finisar | FTLX1475D3BCL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | Finisar | FTLX1475D3BCL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E2 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | Finisar | FTLX1475D3BCV | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-4 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | Finisar | FTLX1475D3BCV | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E3 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | Finisar | FTLX1475D3BCV | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E3 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | Finisar | FTLX1475D3BCV | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A11 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | Finisar | FTLX1475D3BCV | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT50B01 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | Finisar | FTLX1475D3BCV | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | Finisar | FTLX1475D3BCV | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 10G | SFP+ | BASE-LR | 802-0039-01-01 | Finisar | FTLX1475D3BCV | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E2 | 10G | SFP+ | BASE-LR | N/A | Lumentum | JSH-01LWAA1 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-4 | 10G | SFP+ | BASE-LR | N/A | Lumentum | JSH-01LWAA1 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E3 | 10G | SFP+ | BASE-LR | N/A | Lumentum | JSH-01LWAA1 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E3 | 10G | SFP+ | BASE-LR | N/A | Lumentum | JSH-01LWAA1 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A11 | 10G | SFP+ | BASE-LR | N/A | Lumentum | JSH-01LWAA1 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT50B01 | 10G | SFP+ | BASE-LR | N/A | Lumentum | JSH-01LWAA1 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 10G | SFP+ | BASE-LR | N/A | Lumentum | JSH-01LWAA1 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 10G | SFP+ | BASE-LR | N/A | Lumentum | JSH-01LWAA1 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E2 | 10G | SFP+ | BASE-LR | N/A | Sumitomo | SPP5200LR-GL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-4 | 10G | SFP+ | BASE-LR | N/A | Sumitomo | SPP5200LR-GL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E3 | 10G | SFP+ | BASE-LR | N/A | Sumitomo | SPP5200LR-GL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E3 | 10G | SFP+ | BASE-LR | N/A | Sumitomo | SPP5200LR-GL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A11 | 10G | SFP+ | BASE-LR | N/A | Sumitomo | SPP5200LR-GL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT50B01 | 10G | SFP+ | BASE-LR | N/A | Sumitomo | SPP5200LR-GL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 10G | SFP+ | BASE-LR | N/A | Sumitomo | SPP5200LR-GL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 10G | SFP+ | BASE-LR | N/A | Sumitomo | SPP5200LR-GL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E2 | 10G | SFP+ | BASE-LR | N/A | Sumitomo | SPP5100LR-GL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-4 | 10G | SFP+ | BASE-LR | N/A | Sumitomo | SPP5100LR-GL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E3 | 10G | SFP+ | BASE-LR | N/A | Sumitomo | SPP5100LR-GL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E3 | 10G | SFP+ | BASE-LR | N/A | Sumitomo | SPP5100LR-GL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A11 | 10G | SFP+ | BASE-LR | N/A | Sumitomo | SPP5100LR-GL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT50B01 | 10G | SFP+ | BASE-LR | N/A | Sumitomo | SPP5100LR-GL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 10G | SFP+ | BASE-LR | N/A | Sumitomo | SPP5100LR-GL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 10G | SFP+ | BASE-LR | N/A | Sumitomo | SPP5100LR-GL | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E2 | 10G | SFP+ | BASE-LR | N/A | Sumitomo | SPP5200LR-GL-M | No | "1.0.0" | I | 0 to 85 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-4 | 10G | SFP+ | BASE-LR | N/A | Sumitomo | SPP5200LR-GL-M | No | "1.0.0" | I | 0 to 85 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E3 | 10G | SFP+ | BASE-LR | N/A | Sumitomo | SPP5200LR-GL-M | No | "1.0.0" | I | 0 to 85 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E3 | 10G | SFP+ | BASE-LR | N/A | Sumitomo | SPP5200LR-GL-M | No | "1.0.0" | I | 0 to 85 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A11 | 10G | SFP+ | BASE-LR | N/A | Sumitomo | SPP5200LR-GL-M | No | "1.0.0" | I | 0 to 85 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT50B01 | 10G | SFP+ | BASE-LR | N/A | Sumitomo | SPP5200LR-GL-M | No | "1.0.0" | I | 0 to 85 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 10G | SFP+ | BASE-LR | N/A | Sumitomo | SPP5200LR-GL-M | No | "1.0.0" | I | 0 to 85 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 10G | SFP+ | BASE-LR | N/A | Sumitomo | SPP5200LR-GL-M | No | "1.0.0" | I | 0 to 85 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E2 | 10G | SFP+ | BASE-LR | N/A | Cisco | 10-2457-02 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40E2-4 | 10G | SFP+ | BASE-LR | N/A | Cisco | 10-2457-02 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT20E3 | 10G | SFP+ | BASE-LR | N/A | Cisco | 10-2457-02 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40E3 | 10G | SFP+ | BASE-LR | N/A | Cisco | 10-2457-02 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40A11 | 10G | SFP+ | BASE-LR | N/A | Cisco | 10-2457-02 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT50B01 | 10G | SFP+ | BASE-LR | N/A | Cisco | 10-2457-02 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT100A01 | 10G | SFP+ | BASE-LR | N/A | Cisco | 10-2457-02 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 10G | SFP+ | BASE-LR | N/A | Cisco | 10-2457-02 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT20E2 | 10G | SFP+ | BASE-LR | N/A | Innolight | TR-PX13L-NRS | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40E2-4 | 10G | SFP+ | BASE-LR | N/A | Innolight | TR-PX13L-NRS | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT20E3 | 10G | SFP+ | BASE-LR | N/A | Innolight | TR-PX13L-NRS | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40E3 | 10G | SFP+ | BASE-LR | N/A | Innolight | TR-PX13L-NRS | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40A11 | 10G | SFP+ | BASE-LR | N/A | Innolight | TR-PX13L-NRS | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT50B01 | 10G | SFP+ | BASE-LR | N/A | Innolight | TR-PX13L-NRS | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT100A01 | 10G | SFP+ | BASE-LR | N/A | Innolight | TR-PX13L-NRS | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 10G | SFP+ | BASE-LR | N/A | Innolight | TR-PX13L-NRS | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT20E2 | 10G | SFP+ | BASE-LR | N/A | Innolight | TR-PX13L-N00 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40E2-4 | 10G | SFP+ | BASE-LR | N/A | Innolight | TR-PX13L-N00 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT20E3 | 10G | SFP+ | BASE-LR | N/A | Innolight | TR-PX13L-N00 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40E3 | 10G | SFP+ | BASE-LR | N/A | Innolight | TR-PX13L-N00 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40A11 | 10G | SFP+ | BASE-LR | N/A | Innolight | TR-PX13L-N00 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT50B01 | 10G | SFP+ | BASE-LR | N/A | Innolight | TR-PX13L-N00 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT100A01 | 10G | SFP+ | BASE-LR | N/A | Innolight | TR-PX13L-N00 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 10G | SFP+ | BASE-LR | N/A | Innolight | TR-PX13L-N00 | No | "1.0.0" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT4E | 1/10G | SFP+ | BASE-LR | 802-0079-01-10 | FIT | AFCT-739DMZ | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT4E2 | 1/10G | SFP+ | BASE-LR | 802-0079-01-10 | FIT | AFCT-739DMZ | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A01 | 1/10G | SFP+ | BASE-LR | 802-0079-01-10 | FIT | AFCT-739DMZ | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E2 | 1/10G | SFP+ | BASE-LR | 802-0079-01-10 | FIT | AFCT-739DMZ | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-4 | 1/10G | SFP+ | BASE-LR | 802-0079-01-10 | FIT | AFCT-739DMZ | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E3 | 1/10G | SFP+ | BASE-LR | 802-0079-01-10 | FIT | AFCT-739DMZ | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E3 | 1/10G | SFP+ | BASE-LR | 802-0079-01-10 | FIT | AFCT-739DMZ | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A11 | 1/10G | SFP+ | BASE-LR | 802-0079-01-10 | FIT | AFCT-739DMZ | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT50B01 | 1/10G | SFP+ | BASE-LR | 802-0079-01-10 | FIT | AFCT-739DMZ | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 1/10G | SFP+ | BASE-LR | 802-0079-01-10 | FIT | AFCT-739DMZ | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 1/10G | SFP+ | BASE-LR | 802-0079-01-10 | FIT | AFCT-739DMZ | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | uk | Yes | Yes | Yes | Yes | Yes | Yes |
NT4E | 1/10G | SFP+ | BASE-LR | 802-0079-01-10 | Finisar | FTLX1471D3BCV | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT4E2 | 1/10G | SFP+ | BASE-LR | 802-0079-01-10 | Finisar | FTLX1471D3BCV | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A01 | 1/10G | SFP+ | BASE-LR | 802-0079-01-10 | Finisar | FTLX1471D3BCV | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E2 | 1/10G | SFP+ | BASE-LR | 802-0079-01-10 | Finisar | FTLX1471D3BCV | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-4 | 1/10G | SFP+ | BASE-LR | 802-0079-01-10 | Finisar | FTLX1471D3BCV | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E3 | 1/10G | SFP+ | BASE-LR | 802-0079-01-10 | Finisar | FTLX1471D3BCV | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E3 | 1/10G | SFP+ | BASE-LR | 802-0079-01-10 | Finisar | FTLX1471D3BCV | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A11 | 1/10G | SFP+ | BASE-LR | 802-0079-01-10 | Finisar | FTLX1471D3BCV | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT50B01 | 1/10G | SFP+ | BASE-LR | 802-0079-01-10 | Finisar | FTLX1471D3BCV | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 1/10G | SFP+ | BASE-LR | 802-0079-01-10 | Finisar | FTLX1471D3BCV | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 1/10G | SFP+ | BASE-LR | 802-0079-01-10 | Finisar | FTLX1471D3BCV | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT4E | 1/10G | SFP+ | BASE-LR | 802-0079-01-10 | Finisar | FTLX1475D3BCV | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT4E2 | 1/10G | SFP+ | BASE-LR | 802-0079-01-10 | Finisar | FTLX1475D3BCV | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A01 | 1/10G | SFP+ | BASE-LR | 802-0079-01-10 | Finisar | FTLX1475D3BCV | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E2 | 1/10G | SFP+ | BASE-LR | 802-0079-01-10 | Finisar | FTLX1475D3BCV | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-4 | 1/10G | SFP+ | BASE-LR | 802-0079-01-10 | Finisar | FTLX1475D3BCV | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E3 | 1/10G | SFP+ | BASE-LR | 802-0079-01-10 | Finisar | FTLX1475D3BCV | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E3 | 1/10G | SFP+ | BASE-LR | 802-0079-01-10 | Finisar | FTLX1475D3BCV | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A11 | 1/10G | SFP+ | BASE-LR | 802-0079-01-10 | Finisar | FTLX1475D3BCV | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT50B01 | 1/10G | SFP+ | BASE-LR | 802-0079-01-10 | Finisar | FTLX1475D3BCV | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 1/10G | SFP+ | BASE-LR | 802-0079-01-10 | Finisar | FTLX1475D3BCV | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 1/10G | SFP+ | BASE-LR | 802-0079-01-10 | Finisar | FTLX1475D3BCV | No | "3.0.1" | I | 0 to 70 | Yes | Bail | LC | N/A | N/A | pw | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E2 | 10G | SFP+ | BASE-ER | N/A | Finisar | FTLX1671D3BCL | No | "1.0.0" | II | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-4 | 10G | SFP+ | BASE-ER | N/A | Finisar | FTLX1671D3BCL | No | "1.0.0" | II | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E3 | 10G | SFP+ | BASE-ER | N/A | Finisar | FTLX1671D3BCL | No | "1.0.0" | II | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E3 | 10G | SFP+ | BASE-ER | N/A | Finisar | FTLX1671D3BCL | No | "1.0.0" | II | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A11 | 10G | SFP+ | BASE-ER | N/A | Finisar | FTLX1671D3BCL | No | "1.0.0" | II | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT50B01 | 10G | SFP+ | BASE-ER | N/A | Finisar | FTLX1671D3BCL | No | "1.0.0" | II | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 10G | SFP+ | BASE-ER | N/A | Finisar | FTLX1671D3BCL | No | "1.0.0" | II | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 10G | SFP+ | BASE-ER | N/A | Finisar | FTLX1671D3BCL | No | "1.0.0" | II | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E2 | 10G | SFP+ | BASE-ER | N/A | Finisar | FTLX1672D3BCL | No | "1.0.0" | II | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40E2-4 | 10G | SFP+ | BASE-ER | N/A | Finisar | FTLX1672D3BCL | No | "1.0.0" | II | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT20E3 | 10G | SFP+ | BASE-ER | N/A | Finisar | FTLX1672D3BCL | No | "1.0.0" | II | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40E3 | 10G | SFP+ | BASE-ER | N/A | Finisar | FTLX1672D3BCL | No | "1.0.0" | II | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40A11 | 10G | SFP+ | BASE-ER | N/A | Finisar | FTLX1672D3BCL | No | "1.0.0" | II | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT50B01 | 10G | SFP+ | BASE-ER | N/A | Finisar | FTLX1672D3BCL | No | "1.0.0" | II | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT100A01 | 10G | SFP+ | BASE-ER | N/A | Finisar | FTLX1672D3BCL | No | "1.0.0" | II | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 10G | SFP+ | BASE-ER | N/A | Finisar | FTLX1672D3BCL | No | "1.0.0" | II | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT20E2 | 10G | SFP+ | BASE-ER | N/A | Sumitomo | SPP5100ER-GL | No | "1.0.0" | II | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-4 | 10G | SFP+ | BASE-ER | N/A | Sumitomo | SPP5100ER-GL | No | "1.0.0" | II | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E3 | 10G | SFP+ | BASE-ER | N/A | Sumitomo | SPP5100ER-GL | No | "1.0.0" | II | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E3 | 10G | SFP+ | BASE-ER | N/A | Sumitomo | SPP5100ER-GL | No | "1.0.0" | II | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A11 | 10G | SFP+ | BASE-ER | N/A | Sumitomo | SPP5100ER-GL | No | "1.0.0" | II | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT50B01 | 10G | SFP+ | BASE-ER | N/A | Sumitomo | SPP5100ER-GL | No | "1.0.0" | II | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 10G | SFP+ | BASE-ER | N/A | Sumitomo | SPP5100ER-GL | No | "1.0.0" | II | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 10G | SFP+ | BASE-ER | N/A | Sumitomo | SPP5100ER-GL | No | "1.0.0" | II | 0 to 70 | Yes | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT4E | 1/10G | SFP+ | BASE-CR | 802-0058-00-00 | FCI | 10110818-5030LF | No | "1.0.0" | I | 0 to 70 | N/A | Strap | N/A | 3 m | 24 AWG | No | N/A | N/A | N/A | N/A | No | Yes |
NT4E2 | 1/10G | SFP+ | BASE-CR | 802-0058-00-00 | FCI | 10110818-5030LF | No | "1.0.0" | I | 0 to 70 | N/A | Strap | N/A | 3 m | 24 AWG | No | N/A | N/A | N/A | N/A | No | Yes |
NT40A01 | 1/10G | SFP+ | BASE-CR | 802-0058-00-00 | FCI | 10110818-5030LF | No | "1.0.0" | I | 0 to 70 | N/A | Strap | N/A | 3 m | 24 AWG | No | N/A | N/A | N/A | N/A | No | Yes |
NT20E2 | 1/10G | SFP+ | BASE-CR | 802-0058-00-00 | FCI | 10110818-5030LF | No | "1.0.0" | I | 0 to 70 | N/A | Strap | N/A | 3 m | 24 AWG | No | N/A | N/A | N/A | N/A | No | Yes |
NT40E2-4 | 1/10G | SFP+ | BASE-CR | 802-0058-00-00 | FCI | 10110818-5030LF | No | "1.0.0" | I | 0 to 70 | N/A | Strap | N/A | 3 m | 24 AWG | No | N/A | N/A | N/A | N/A | No | Yes |
NT20E3 | 1/10G | SFP+ | BASE-CR | 802-0058-00-00 | FCI | 10110818-5030LF | No | "1.0.0" | I | 0 to 70 | N/A | Strap | N/A | 3 m | 24 AWG | No | N/A | N/A | N/A | N/A | No | Yes |
NT40E3 | 1/10G | SFP+ | BASE-CR | 802-0058-00-00 | FCI | 10110818-5030LF | No | "1.0.0" | I | 0 to 70 | N/A | Strap | N/A | 3 m | 24 AWG | No | N/A | N/A | N/A | N/A | No | Yes |
NT40A11 | 1/10G | SFP+ | BASE-CR | 802-0058-00-00 | FCI | 10110818-5030LF | No | "1.0.0" | I | 0 to 70 | N/A | Strap | N/A | 3 m | 24 AWG | No | N/A | N/A | N/A | N/A | No | Yes |
NT50B01 | 1/10G | SFP+ | BASE-CR | 802-0058-00-00 | FCI | 10110818-5030LF | No | "1.0.0" | I | 0 to 70 | N/A | Strap | N/A | 3 m | 24 AWG | No | N/A | N/A | N/A | N/A | No | Yes |
NT100A01 | 1/10G | SFP+ | BASE-CR | 802-0058-00-00 | FCI | 10110818-5030LF | No | "1.0.0" | I | 0 to 70 | N/A | Strap | N/A | 3 m | 24 AWG | No | N/A | N/A | N/A | N/A | No | Yes |
NT200A02 | 1/10G | SFP+ | BASE-CR | 802-0058-00-00 | FCI | 10110818-5030LF | No | "1.0.0" | I | 0 to 70 | N/A | Strap | N/A | 3 m | 24 AWG | No | N/A | N/A | N/A | N/A | No | Yes |
NT4E | 1/10G | SFP+ | BASE-CR | N/A | Cisco | SFP-H10GB-ACU10M | No | "1.0.0" | I | 0 to 70 | N/A | Strap | N/A | 10 m | 28 AWG | No | N/A | N/A | N/A | N/A | No | No |
NT4E2 | 1/10G | SFP+ | BASE-CR | N/A | Cisco | SFP-H10GB-ACU10M | No | "1.0.0" | I | 0 to 70 | N/A | Strap | N/A | 10 m | 28 AWG | No | N/A | N/A | N/A | N/A | No | No |
NT40A01 | 1/10G | SFP+ | BASE-CR | N/A | Cisco | SFP-H10GB-ACU10M | No | "1.0.0" | I | 0 to 70 | N/A | Strap | N/A | 10 m | 28 AWG | No | N/A | N/A | N/A | N/A | No | No |
NT20E2 | 1/10G | SFP+ | BASE-CR | N/A | Cisco | SFP-H10GB-ACU10M | No | "1.0.0" | I | 0 to 70 | N/A | Strap | N/A | 10 m | 28 AWG | No | N/A | N/A | N/A | N/A | No | No |
NT40E2-4 | 1/10G | SFP+ | BASE-CR | N/A | Cisco | SFP-H10GB-ACU10M | No | "1.0.0" | I | 0 to 70 | N/A | Strap | N/A | 10 m | 28 AWG | No | N/A | N/A | N/A | N/A | No | No |
NT20E3 | 1/10G | SFP+ | BASE-CR | N/A | Cisco | SFP-H10GB-ACU10M | No | "1.0.0" | I | 0 to 70 | N/A | Strap | N/A | 10 m | 28 AWG | No | N/A | N/A | N/A | N/A | No | No |
NT40E3 | 1/10G | SFP+ | BASE-CR | N/A | Cisco | SFP-H10GB-ACU10M | No | "1.0.0" | I | 0 to 70 | N/A | Strap | N/A | 10 m | 28 AWG | No | N/A | N/A | N/A | N/A | No | No |
NT40A11 | 1/10G | SFP+ | BASE-CR | N/A | Cisco | SFP-H10GB-ACU10M | No | "1.0.0" | I | 0 to 70 | N/A | Strap | N/A | 10 m | 28 AWG | No | N/A | N/A | N/A | N/A | No | No |
NT50B01 | 1/10G | SFP+ | BASE-CR | N/A | Cisco | SFP-H10GB-ACU10M | No | "1.0.0" | I | 0 to 70 | N/A | Strap | N/A | 10 m | 28 AWG | No | N/A | N/A | N/A | N/A | No | No |
NT100A01 | 1/10G | SFP+ | BASE-CR | N/A | Cisco | SFP-H10GB-ACU10M | No | "1.0.0" | I | 0 to 70 | N/A | Strap | N/A | 10 m | 28 AWG | No | N/A | N/A | N/A | N/A | No | No |
NT200A02 | 1/10G | SFP+ | BASE-CR | N/A | Cisco | SFP-H10GB-ACU10M | No | "1.0.0" | I | 0 to 70 | N/A | Strap | N/A | 10 m | 28 AWG | No | N/A | N/A | N/A | N/A | No | No |
NT50B01 | 25G | SFP28 | BASE-SR | 802-0088-01-10 | Innolight | TR-PY85S-N00 | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 25G | SFP28 | BASE-SR | 802-0088-01-10 | Innolight | TR-PY85S-N00 | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A01 | 25G | SFP28 | BASE-SR | 802-0088-01-10 | Innolight | TR-PY85S-N00 | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 25G | SFP28 | BASE-SR | 802-0088-01-10 | Innolight | TR-PY85S-N00 | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT50B01 | 25G | SFP28 | BASE-SR | 802-0088-01-10 | Innolight | TR-PZ85S-N00 | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 25G | SFP28 | BASE-SR | 802-0088-01-10 | Innolight | TR-PZ85S-N00 | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A01 | 25G | SFP28 | BASE-SR | 802-0088-01-10 | Innolight | TR-PZ85S-N00 | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 25G | SFP28 | BASE-SR | 802-0088-01-10 | Innolight | TR-PZ85S-N00 | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT50B01 | 25G | SFP28 | BASE-SR | 802-0088-01-10-01 | Finisar | FTLF8536P4BCV | Yes | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 25G | SFP28 | BASE-SR | 802-0088-01-10-01 | Finisar | FTLF8536P4BCV | Yes | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A01 | 25G | SFP28 | BASE-SR | 802-0088-01-10-01 | Finisar | FTLF8536P4BCV | Yes | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 25G | SFP28 | BASE-SR | 802-0088-01-10-01 | Finisar | FTLF8536P4BCV | Yes | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E2 | 10/25G | SFP28 | BASE-SR | 802-0086-01-10 | Innolight | TR-PZ85S-N00 | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-4 | 10/25G | SFP28 | BASE-SR | 802-0086-01-10 | Innolight | TR-PZ85S-N00 | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E3 | 10/25G | SFP28 | BASE-SR | 802-0086-01-10 | Innolight | TR-PZ85S-N00 | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E3 | 10/25G | SFP28 | BASE-SR | 802-0086-01-10 | Innolight | TR-PZ85S-N00 | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A11 | 10/25G | SFP28 | BASE-SR | 802-0086-01-10 | Innolight | TR-PZ85S-N00 | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT50B01 | 10/25G | SFP28 | BASE-SR | 802-0086-01-10 | Innolight | TR-PZ85S-N00 | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 10/25G | SFP28 | BASE-SR | 802-0086-01-10 | Innolight | TR-PZ85S-N00 | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A01 | 10/25G | SFP28 | BASE-SR | 802-0086-01-10 | Innolight | TR-PZ85S-N00 | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 10/25G | SFP28 | BASE-SR | 802-0086-01-10 | Innolight | TR-PZ85S-N00 | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E2 | 10/25G | SFP28 | BASE-SR | 802-0086-01-10-01 | Finisar | FTLF8536P4BCV | Yes | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-4 | 10/25G | SFP28 | BASE-SR | 802-0086-01-10-01 | Finisar | FTLF8536P4BCV | Yes | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E3 | 10/25G | SFP28 | BASE-SR | 802-0086-01-10-01 | Finisar | FTLF8536P4BCV | Yes | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E3 | 10/25G | SFP28 | BASE-SR | 802-0086-01-10-01 | Finisar | FTLF8536P4BCV | Yes | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A11 | 10/25G | SFP28 | BASE-SR | 802-0086-01-10-01 | Finisar | FTLF8536P4BCV | Yes | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT50B01 | 10/25G | SFP28 | BASE-SR | 802-0086-01-10-01 | Finisar | FTLF8536P4BCV | Yes | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 10/25G | SFP28 | BASE-SR | 802-0086-01-10-01 | Finisar | FTLF8536P4BCV | Yes | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A01 | 10/25G | SFP28 | BASE-SR | 802-0086-01-10-01 | Finisar | FTLF8536P4BCV | Yes | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 10/25G | SFP28 | BASE-SR | 802-0086-01-10-01 | Finisar | FTLF8536P4BCV | Yes | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT50B01 | 25G | SFP28 | BASE-LR | 802-0089-01-10 | Innolight | TR-PY13L-N00 | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 25G | SFP28 | BASE-LR | 802-0089-01-10 | Innolight | TR-PY13L-N00 | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A01 | 25G | SFP28 | BASE-LR | 802-0089-01-10 | Innolight | TR-PY13L-N00 | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 25G | SFP28 | BASE-LR | 802-0089-01-10 | Innolight | TR-PY13L-N00 | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT50B01 | 25G | SFP28 | BASE-LR | 802-0089-01-10 | Innolight | TR-PZ13L-N00 | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 25G | SFP28 | BASE-LR | 802-0089-01-10 | Innolight | TR-PZ13L-N00 | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A01 | 25G | SFP28 | BASE-LR | 802-0089-01-10 | Innolight | TR-PZ13L-N00 | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 25G | SFP28 | BASE-LR | 802-0089-01-10 | Innolight | TR-PZ13L-N00 | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT50B01 | 25G | SFP28 | BASE-LR | 802-0089-01-10-01 | Finisar | FTLF1436P4BCV | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 25G | SFP28 | BASE-LR | 802-0089-01-10-01 | Finisar | FTLF1436P4BCV | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A01 | 25G | SFP28 | BASE-LR | 802-0089-01-10-01 | Finisar | FTLF1436P4BCV | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 25G | SFP28 | BASE-LR | 802-0089-01-10-01 | Finisar | FTLF1436P4BCV | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E2 | 10/25G | SFP28 | BASE-LR | 802-0087-01-10 | Innolight | TR-PZ13L-N00 | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-4 | 10/25G | SFP28 | BASE-LR | 802-0087-01-10 | Innolight | TR-PZ13L-N00 | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E3 | 10/25G | SFP28 | BASE-LR | 802-0087-01-10 | Innolight | TR-PZ13L-N00 | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E3 | 10/25G | SFP28 | BASE-LR | 802-0087-01-10 | Innolight | TR-PZ13L-N00 | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A11 | 10/25G | SFP28 | BASE-LR | 802-0087-01-10 | Innolight | TR-PZ13L-N00 | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT50B01 | 10/25G | SFP28 | BASE-LR | 802-0087-01-10 | Innolight | TR-PZ13L-N00 | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 10/25G | SFP28 | BASE-LR | 802-0087-01-10 | Innolight | TR-PZ13L-N00 | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A01 | 10/25G | SFP28 | BASE-LR | 802-0087-01-10 | Innolight | TR-PZ13L-N00 | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 10/25G | SFP28 | BASE-LR | 802-0087-01-10 | Innolight | TR-PZ13L-N00 | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E2 | 10/25G | SFP28 | BASE-LR | 802-0087-01-10-01 | Finisar | FTLF1436P4BCV | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-4 | 10/25G | SFP28 | BASE-LR | 802-0087-01-10-01 | Finisar | FTLF1436P4BCV | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT20E3 | 10/25G | SFP28 | BASE-LR | 802-0087-01-10-01 | Finisar | FTLF1436P4BCV | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E3 | 10/25G | SFP28 | BASE-LR | 802-0087-01-10-01 | Finisar | FTLF1436P4BCV | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40A11 | 10/25G | SFP28 | BASE-LR | 802-0087-01-10-01 | Finisar | FTLF1436P4BCV | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT50B01 | 10/25G | SFP28 | BASE-LR | 802-0087-01-10-01 | Finisar | FTLF1436P4BCV | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT100A01 | 10/25G | SFP28 | BASE-LR | 802-0087-01-10-01 | Finisar | FTLF1436P4BCV | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A01 | 10/25G | SFP28 | BASE-LR | 802-0087-01-10-01 | Finisar | FTLF1436P4BCV | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 10/25G | SFP28 | BASE-LR | 802-0087-01-10-01 | Finisar | FTLF1436P4BCV | No | "3.13.3" | I | 0 to 70 | No | Bail | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-1 | 40G | QSFP+ | BASE-SR4 | 802-0049-01-01 | FIT | AFBR-79E4Z | Yes | "1.0.0" | 1 | 0 to 70 | N/A | Bail | MPO | N/A | N/A | Yes | Yes | No | No | No | Yes | Yes |
NT80E3 | 40G | QSFP+ | BASE-SR4 | 802-0049-01-01 | FIT | AFBR-79E4Z | Yes | "1.0.0" | 1 | 0 to 70 | N/A | Bail | MPO | N/A | N/A | Yes | Yes | No | No | No | Yes | Yes |
NT200A01 | 40G | QSFP+ | BASE-SR4 | 802-0049-01-01 | FIT | AFBR-79E4Z | Yes | "1.0.0" | 1 | 0 to 70 | N/A | Bail | MPO | N/A | N/A | Yes | Yes | No | No | No | Yes | Yes |
NT200A02 | 40G | QSFP+ | BASE-SR4 | 802-0049-01-01 | FIT | AFBR-79E4Z | Yes | "1.0.0" | 1 | 0 to 70 | N/A | Bail | MPO | N/A | N/A | Yes | Yes | No | No | No | Yes | Yes |
NT40E2-1 | 4x10G breakout | QSFP+ | BASE-SR4 | 802-0049-01-01 | FIT | AFBR-79E4Z | Yes | "1.0.0" | 1 | 0 to 70 | N/A | Bail | MPO | N/A | N/A | Yes | Yes | No | No | No | Yes | Yes |
NT80E3 | 4x10G breakout | QSFP+ | BASE-SR4 | 802-0049-01-01 | FIT | AFBR-79E4Z | Yes | "1.0.0" | 1 | 0 to 70 | N/A | Bail | MPO | N/A | N/A | Yes | Yes | No | No | No | Yes | Yes |
NT200A01 | 4x10G breakout | QSFP+ | BASE-SR4 | 802-0049-01-01 | FIT | AFBR-79E4Z | Yes | "1.0.0" | 1 | 0 to 70 | N/A | Bail | MPO | N/A | N/A | Yes | Yes | No | No | No | Yes | Yes |
NT200A02 | 4x10G breakout | QSFP+ | BASE-SR4 | 802-0049-01-01 | FIT | AFBR-79E4Z | Yes | "1.0.0" | 1 | 0 to 70 | N/A | Bail | MPO | N/A | N/A | Yes | Yes | No | No | No | Yes | Yes |
NT40E2-1 | 40G | QSFP+ | BASE-SR4 | 802-0049-01-01 | FIT | AFBR-79E4Z-D | Yes | "1.0.0" | 1 | 0 to 70 | N/A | Bail | MPO | N/A | N/A | Yes | Yes | Yes | Yes | No | Yes | Yes |
NT80E3 | 40G | QSFP+ | BASE-SR4 | 802-0049-01-01 | FIT | AFBR-79E4Z-D | Yes | "1.0.0" | 1 | 0 to 70 | N/A | Bail | MPO | N/A | N/A | Yes | Yes | Yes | Yes | No | Yes | Yes |
NT200A01 | 40G | QSFP+ | BASE-SR4 | 802-0049-01-01 | FIT | AFBR-79E4Z-D | Yes | "1.0.0" | 1 | 0 to 70 | N/A | Bail | MPO | N/A | N/A | Yes | Yes | Yes | Yes | No | Yes | Yes |
NT200A02 | 40G | QSFP+ | BASE-SR4 | 802-0049-01-01 | FIT | AFBR-79E4Z-D | Yes | "1.0.0" | 1 | 0 to 70 | N/A | Bail | MPO | N/A | N/A | Yes | Yes | Yes | Yes | No | Yes | Yes |
NT40E2-1 | 4x10G breakout | QSFP+ | BASE-SR4 | 802-0049-01-01 | FIT | AFBR-79E4Z-D | Yes | "1.0.0" | 1 | 0 to 70 | N/A | Bail | MPO | N/A | N/A | Yes | Yes | Yes | Yes | No | Yes | Yes |
NT80E3 | 4x10G breakout | QSFP+ | BASE-SR4 | 802-0049-01-01 | FIT | AFBR-79E4Z-D | Yes | "1.0.0" | 1 | 0 to 70 | N/A | Bail | MPO | N/A | N/A | Yes | Yes | Yes | Yes | No | Yes | Yes |
NT200A01 | 4x10G breakout | QSFP+ | BASE-SR4 | 802-0049-01-01 | FIT | AFBR-79E4Z-D | Yes | "1.0.0" | 1 | 0 to 70 | N/A | Bail | MPO | N/A | N/A | Yes | Yes | Yes | Yes | No | Yes | Yes |
NT200A02 | 4x10G breakout | QSFP+ | BASE-SR4 | 802-0049-01-01 | FIT | AFBR-79E4Z-D | Yes | "1.0.0" | 1 | 0 to 70 | N/A | Bail | MPO | N/A | N/A | Yes | Yes | Yes | Yes | No | Yes | Yes |
NT40E2-1 | 40G | QSFP+ | BASE-SR4 | 802-0049-01-01 | FIT | AFBR-79EQDZ | No | "3.0.1" | 1 | 0 to 70 | N/A | Bail | MPO | N/A | N/A | Yes | Yes | Yes | Yes | No | Yes | Yes |
NT80E3 | 40G | QSFP+ | BASE-SR4 | 802-0049-01-01 | FIT | AFBR-79EQDZ | No | "3.0.1" | 1 | 0 to 70 | N/A | Bail | MPO | N/A | N/A | Yes | Yes | Yes | Yes | No | Yes | Yes |
NT200A01 | 40G | QSFP+ | BASE-SR4 | 802-0049-01-01 | FIT | AFBR-79EQDZ | No | "3.0.1" | 1 | 0 to 70 | N/A | Bail | MPO | N/A | N/A | Yes | Yes | Yes | Yes | No | Yes | Yes |
NT200A02 | 40G | QSFP+ | BASE-SR4 | 802-0049-01-01 | FIT | AFBR-79EQDZ | No | "3.0.1" | 1 | 0 to 70 | N/A | Bail | MPO | N/A | N/A | Yes | Yes | Yes | Yes | No | Yes | Yes |
NT40E2-1 | 4x10G breakout | QSFP+ | BASE-SR4 | 802-0049-01-01 | FIT | AFBR-79EQDZ | No | "3.0.1" | 1 | 0 to 70 | N/A | Bail | MPO | N/A | N/A | Yes | Yes | Yes | Yes | No | Yes | Yes |
NT80E3 | 4x10G breakout | QSFP+ | BASE-SR4 | 802-0049-01-01 | FIT | AFBR-79EQDZ | No | "3.0.1" | 1 | 0 to 70 | N/A | Bail | MPO | N/A | N/A | Yes | Yes | Yes | Yes | No | Yes | Yes |
NT200A01 | 4x10G breakout | QSFP+ | BASE-SR4 | 802-0049-01-01 | FIT | AFBR-79EQDZ | No | "3.0.1" | 1 | 0 to 70 | N/A | Bail | MPO | N/A | N/A | Yes | Yes | Yes | Yes | No | Yes | Yes |
NT200A02 | 4x10G breakout | QSFP+ | BASE-SR4 | 802-0049-01-01 | FIT | AFBR-79EQDZ | No | "3.0.1" | 1 | 0 to 70 | N/A | Bail | MPO | N/A | N/A | Yes | Yes | Yes | Yes | No | Yes | Yes |
NT40E2-1 | 40G | QSFP+ | BASE-SR4 | 802-0049-01-01 | FIT | AFBR-79EQPZ | No | "1.0.0" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT80E3 | 40G | QSFP+ | BASE-SR4 | 802-0049-01-01 | FIT | AFBR-79EQPZ | No | "1.0.0" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A01 | 40G | QSFP+ | BASE-SR4 | 802-0049-01-01 | FIT | AFBR-79EQPZ | No | "1.0.0" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 40G | QSFP+ | BASE-SR4 | 802-0049-01-01 | FIT | AFBR-79EQPZ | No | "1.0.0" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-1 | 4x10G breakout | QSFP+ | BASE-SR4 | 802-0049-01-01 | FIT | AFBR-79EQPZ | No | "1.0.0" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT80E3 | 4x10G breakout | QSFP+ | BASE-SR4 | 802-0049-01-01 | FIT | AFBR-79EQPZ | No | "1.0.0" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A01 | 4x10G breakout | QSFP+ | BASE-SR4 | 802-0049-01-01 | FIT | AFBR-79EQPZ | No | "1.0.0" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 4x10G breakout | QSFP+ | BASE-SR4 | 802-0049-01-01 | FIT | AFBR-79EQPZ | No | "1.0.0" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-1 | 40G | QSFP+ | BASE-SR4 | 802-0049-01-01 | Finisar | FTL410QE3C | No | "3.0.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT80E3 | 40G | QSFP+ | BASE-SR4 | 802-0049-01-01 | Finisar | FTL410QE3C | No | "3.0.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A01 | 40G | QSFP+ | BASE-SR4 | 802-0049-01-01 | Finisar | FTL410QE3C | No | "3.0.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 40G | QSFP+ | BASE-SR4 | 802-0049-01-01 | Finisar | FTL410QE3C | No | "3.0.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-1 | 4x10G breakout | QSFP+ | BASE-SR4 | 802-0049-01-01 | Finisar | FTL410QE3C | No | "3.0.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT80E3 | 4x10G breakout | QSFP+ | BASE-SR4 | 802-0049-01-01 | Finisar | FTL410QE3C | No | "3.0.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A01 | 4x10G breakout | QSFP+ | BASE-SR4 | 802-0049-01-01 | Finisar | FTL410QE3C | No | "3.0.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 4x10G breakout | QSFP+ | BASE-SR4 | 802-0049-01-01 | Finisar | FTL410QE3C | No | "3.0.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-1 | 40G | QSFP+ | BASE-SR4 | 802-0049-01-01 | Finisar | FTL410QE4C | No | "3.8.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT80E3 | 40G | QSFP+ | BASE-SR4 | 802-0049-01-01 | Finisar | FTL410QE4C | No | "3.8.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A01 | 40G | QSFP+ | BASE-SR4 | 802-0049-01-01 | Finisar | FTL410QE4C | No | "3.8.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 40G | QSFP+ | BASE-SR4 | 802-0049-01-01 | Finisar | FTL410QE4C | No | "3.8.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-1 | 4x10G breakout | QSFP+ | BASE-SR4 | 802-0049-01-01 | Finisar | FTL410QE4C | No | "3.8.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT80E3 | 4x10G breakout | QSFP+ | BASE-SR4 | 802-0049-01-01 | Finisar | FTL410QE4C | No | "3.8.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A01 | 4x10G breakout | QSFP+ | BASE-SR4 | 802-0049-01-01 | Finisar | FTL410QE4C | No | "3.8.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 4x10G breakout | QSFP+ | BASE-SR4 | 802-0049-01-01 | Finisar | FTL410QE4C | No | "3.8.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-1 | 40G | QSFP+ | BASE-SR4 | N/A | Finisar | FTL410QE1C | Yes | "2.7.4" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | No | Yes | Yes | No | Yes | Yes | Yes |
NT80E3 | 40G | QSFP+ | BASE-SR4 | N/A | Finisar | FTL410QE1C | Yes | "2.7.4" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | No | Yes | Yes | No | Yes | Yes | Yes |
NT200A01 | 40G | QSFP+ | BASE-SR4 | N/A | Finisar | FTL410QE1C | Yes | "2.7.4" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | No | Yes | Yes | No | Yes | Yes | Yes |
NT200A02 | 40G | QSFP+ | BASE-SR4 | N/A | Finisar | FTL410QE1C | Yes | "2.7.4" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | No | Yes | Yes | No | Yes | Yes | Yes |
NT40E2-1 | 4x10G breakout | QSFP+ | BASE-SR4 | N/A | Finisar | FTL410QE1C | Yes | "2.7.4" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | No | Yes | Yes | No | Yes | Yes | Yes |
NT80E3 | 4x10G breakout | QSFP+ | BASE-SR4 | N/A | Finisar | FTL410QE1C | Yes | "2.7.4" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | No | Yes | Yes | No | Yes | Yes | Yes |
NT200A01 | 4x10G breakout | QSFP+ | BASE-SR4 | N/A | Finisar | FTL410QE1C | Yes | "2.7.4" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | No | Yes | Yes | No | Yes | Yes | Yes |
NT200A02 | 4x10G breakout | QSFP+ | BASE-SR4 | N/A | Finisar | FTL410QE1C | Yes | "2.7.4" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | No | Yes | Yes | No | Yes | Yes | Yes |
NT40E2-1 | 40G | QSFP+ | BASE-SR4 | N/A | Finisar | FTL410QD4C | No | "3.8.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT80E3 | 40G | QSFP+ | BASE-SR4 | N/A | Finisar | FTL410QD4C | No | "3.8.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 40G | QSFP+ | BASE-SR4 | N/A | Finisar | FTL410QD4C | No | "3.8.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 40G | QSFP+ | BASE-SR4 | N/A | Finisar | FTL410QD4C | No | "3.8.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40E2-1 | 4x10G breakout | QSFP+ | BASE-SR4 | N/A | Finisar | FTL410QD4C | No | "3.8.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT80E3 | 4x10G breakout | QSFP+ | BASE-SR4 | N/A | Finisar | FTL410QD4C | No | "3.8.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 4x10G breakout | QSFP+ | BASE-SR4 | N/A | Finisar | FTL410QD4C | No | "3.8.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 4x10G breakout | QSFP+ | BASE-SR4 | N/A | Finisar | FTL410QD4C | No | "3.8.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40E2-1 | 40G | QSFP+ | BASE-SR4 | N/A | Innolight | TR-QQ85S-N00 | No | "3.8.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT80E3 | 40G | QSFP+ | BASE-SR4 | N/A | Innolight | TR-QQ85S-N00 | No | "3.8.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 40G | QSFP+ | BASE-SR4 | N/A | Innolight | TR-QQ85S-N00 | No | "3.8.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 40G | QSFP+ | BASE-SR4 | N/A | Innolight | TR-QQ85S-N00 | No | "3.8.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40E2-1 | 4x10G breakout | QSFP+ | BASE-SR4 | N/A | Innolight | TR-QQ85S-N00 | No | "3.8.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT80E3 | 4x10G breakout | QSFP+ | BASE-SR4 | N/A | Innolight | TR-QQ85S-N00 | No | "3.8.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 4x10G breakout | QSFP+ | BASE-SR4 | N/A | Innolight | TR-QQ85S-N00 | No | "3.8.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 4x10G breakout | QSFP+ | BASE-SR4 | N/A | Innolight | TR-QQ85S-N00 | No | "3.8.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40E2-1 | 40G | QSFP+ | BASE-SR4 | N/A | Innolight | TR-QQ85S-N00 Gen-2 | No | "3.8.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT80E3 | 40G | QSFP+ | BASE-SR4 | N/A | Innolight | TR-QQ85S-N00 Gen-2 | No | "3.8.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 40G | QSFP+ | BASE-SR4 | N/A | Innolight | TR-QQ85S-N00 Gen-2 | No | "3.8.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 40G | QSFP+ | BASE-SR4 | N/A | Innolight | TR-QQ85S-N00 Gen-2 | No | "3.8.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40E2-1 | 4x10G breakout | QSFP+ | BASE-SR4 | N/A | Innolight | TR-QQ85S-N00 Gen-2 | No | "3.8.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT80E3 | 4x10G breakout | QSFP+ | BASE-SR4 | N/A | Innolight | TR-QQ85S-N00 Gen-2 | No | "3.8.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 4x10G breakout | QSFP+ | BASE-SR4 | N/A | Innolight | TR-QQ85S-N00 Gen-2 | No | "3.8.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 4x10G breakout | QSFP+ | BASE-SR4 | N/A | Innolight | TR-QQ85S-N00 Gen-2 | No | "3.8.1" | 1 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40E2-1 | 40G | QSFP+ | BASE-LR4 | 802-0061-01-01 | Finisar | FTL4C1QE1C | Yes | "3.1.1" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | Yes |
NT80E3 | 40G | QSFP+ | BASE-LR4 | 802-0061-01-01 | Finisar | FTL4C1QE1C | Yes | "3.1.1" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A01 | 40G | QSFP+ | BASE-LR4 | 802-0061-01-01 | Finisar | FTL4C1QE1C | Yes | "3.1.1" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 40G | QSFP+ | BASE-LR4 | 802-0061-01-01 | Finisar | FTL4C1QE1C | Yes | "3.1.1" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-1 | 40G | QSFP+ | BASE-LR4 | 802-0061-01-01 | Finisar | FTL4C1QE2C | Yes | "3.8.1" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | Yes |
NT80E3 | 40G | QSFP+ | BASE-LR4 | 802-0061-01-01 | Finisar | FTL4C1QE2C | Yes | "3.8.1" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A01 | 40G | QSFP+ | BASE-LR4 | 802-0061-01-01 | Finisar | FTL4C1QE2C | Yes | "3.8.1" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 40G | QSFP+ | BASE-LR4 | 802-0061-01-01 | Finisar | FTL4C1QE2C | Yes | "3.8.1" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-1 | 40G | QSFP+ | BASE-LR4 | 802-0061-01-01 | Finisar | FTL4C1QE3C | No | "3.8.1" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | Yes |
NT80E3 | 40G | QSFP+ | BASE-LR4 | 802-0061-01-01 | Finisar | FTL4C1QE3C | No | "3.8.1" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A01 | 40G | QSFP+ | BASE-LR4 | 802-0061-01-01 | Finisar | FTL4C1QE3C | No | "3.8.1" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 40G | QSFP+ | BASE-LR4 | 802-0061-01-01 | Finisar | FTL4C1QE3C | No | "3.8.1" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-1 | 40G | QSFP+ | BASE-LR4 | 802-0061-01-01 | Innolight | TR-QQ13L-N00 | No | "3.8.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | Yes |
NT80E3 | 40G | QSFP+ | BASE-LR4 | 802-0061-01-01 | Innolight | TR-QQ13L-N00 | No | "3.8.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A01 | 40G | QSFP+ | BASE-LR4 | 802-0061-01-01 | Innolight | TR-QQ13L-N00 | No | "3.8.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 40G | QSFP+ | BASE-LR4 | 802-0061-01-01 | Innolight | TR-QQ13L-N00 | No | "3.8.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | Yes |
NT40E2-1 | 40G | QSFP+ | BASE-LR4 | N/A | AMC Optics | SPQ-10E-LR-CDFP | No | "3.8.1" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | No |
NT80E3 | 40G | QSFP+ | BASE-LR4 | N/A | AMC Optics | SPQ-10E-LR-CDFP | No | "3.8.1" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 40G | QSFP+ | BASE-LR4 | N/A | AMC Optics | SPQ-10E-LR-CDFP | No | "3.8.1" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 40G | QSFP+ | BASE-LR4 | N/A | AMC Optics | SPQ-10E-LR-CDFP | No | "3.8.1" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | No |
NT40E2-1 | 40G | QSFP+ | BASE-LR4 Lite | N/A | Finisar | FTL4C1QL2C | No | "3.8.1" | 3 | 0 to 70 | N/A | Strap | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | No |
NT80E3 | 40G | QSFP+ | BASE-LR4 Lite | N/A | Finisar | FTL4C1QL2C | No | "3.8.1" | 3 | 0 to 70 | N/A | Strap | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 40G | QSFP+ | BASE-LR4 Lite | N/A | Finisar | FTL4C1QL2C | No | "3.8.1" | 3 | 0 to 70 | N/A | Strap | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 40G | QSFP+ | BASE-LR4 Lite | N/A | Finisar | FTL4C1QL2C | No | "3.8.1" | 3 | 0 to 70 | N/A | Strap | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | No |
NT40E2-1 | 40G | QSFP+ | BASE-LR4 Lite | N/A | Finisar | FTL4C1QL2L | No | "3.8.1" | 3 | 15 to 60 | N/A | Strap | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | No |
NT80E3 | 40G | QSFP+ | BASE-LR4 Lite | N/A | Finisar | FTL4C1QL2L | No | "3.8.1" | 3 | 15 to 60 | N/A | Strap | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 40G | QSFP+ | BASE-LR4 Lite | N/A | Finisar | FTL4C1QL2L | No | "3.8.1" | 3 | 15 to 60 | N/A | Strap | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 40G | QSFP+ | BASE-LR4 Lite | N/A | Finisar | FTL4C1QL2L | No | "3.8.1" | 3 | 15 to 60 | N/A | Strap | LC | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | No |
NT40E2-1 | 40G | QSFP+ | BASE-PSM4 | 802-0095-01-10 | Innolight | TR-IQ13L-N00 | No | "3.8.1" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | No |
NT80E3 | 40G | QSFP+ | BASE-PSM4 | 802-0095-01-10 | Innolight | TR-IQ13L-N00 | No | "3.8.1" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 40G | QSFP+ | BASE-PSM4 | 802-0095-01-10 | Innolight | TR-IQ13L-N00 | No | "3.8.1" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 40G | QSFP+ | BASE-PSM4 | 802-0095-01-10 | Innolight | TR-IQ13L-N00 | No | "3.8.1" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | No |
NT40E2-1 | 4x10G breakout | QSFP+ | BASE-PSM4 | 802-0095-01-10 | Innolight | TR-IQ13L-N00 | No | "3.8.1" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | No |
NT80E3 | 4x10G breakout | QSFP+ | BASE-PSM4 | 802-0095-01-10 | Innolight | TR-IQ13L-N00 | No | "3.8.1" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 4x10G breakout | QSFP+ | BASE-PSM4 | 802-0095-01-10 | Innolight | TR-IQ13L-N00 | No | "3.8.1" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 4x10G breakout | QSFP+ | BASE-PSM4 | 802-0095-01-10 | Innolight | TR-IQ13L-N00 | No | "3.8.1" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | No | Yes | Yes | Yes | Yes | Yes | No |
NT40E2-1 | 40G | QSFP+ | BASE-SR4 BiDi | N/A | FIT | AFBR-79EBRZ | No | "3.6.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | No | No | No | No | No | na | No |
NT80E3 | 40G | QSFP+ | BASE-SR4 BiDi | N/A | FIT | AFBR-79EBRZ | No | "3.6.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | No | No | No | No | No | na | No |
NT200A01 | 40G | QSFP+ | BASE-SR4 BiDi | N/A | FIT | AFBR-79EBRZ | No | "3.6.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | No | No | No | No | No | na | No |
NT200A02 | 40G | QSFP+ | BASE-SR4 BiDi | N/A | FIT | AFBR-79EBRZ | No | "3.6.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | No | No | No | No | No | na | No |
NT40E2-1 | 40G | QSFP+ | BASE-SR4 BiDi | N/A | FIT | AFBR-79EBRZ-DC5 | No | "3.8.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | No | No | No | No | No | na | No |
NT80E3 | 40G | QSFP+ | BASE-SR4 BiDi | N/A | FIT | AFBR-79EBRZ-DC5 | No | "3.8.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | No | No | No | No | No | na | No |
NT200A01 | 40G | QSFP+ | BASE-SR4 BiDi | N/A | FIT | AFBR-79EBRZ-DC5 | No | "3.8.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | No | No | No | No | No | na | No |
NT200A02 | 40G | QSFP+ | BASE-SR4 BiDi | N/A | FIT | AFBR-79EBRZ-DC5 | No | "3.8.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | No | No | No | No | No | na | No |
NT40E2-1 | 40G | QSFP+ | BASE-SR4 BiDi | N/A | FIT | AFBR-79EBMZ | No | "3.8.0" | 4 | 10 to 70 | N/A | Strap | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT80E3 | 40G | QSFP+ | BASE-SR4 BiDi | N/A | FIT | AFBR-79EBMZ | No | "3.8.0" | 4 | 10 to 70 | N/A | Strap | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 40G | QSFP+ | BASE-SR4 BiDi | N/A | FIT | AFBR-79EBMZ | No | "3.8.0" | 4 | 10 to 70 | N/A | Strap | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 40G | QSFP+ | BASE-SR4 BiDi | N/A | FIT | AFBR-79EBMZ | No | "3.8.0" | 4 | 10 to 70 | N/A | Strap | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40E2-1 | 40G | QSFP+ | BASE-SR4 BiDi | N/A | AMC Optics | QSFP40GSBDAMC | No | "3.8.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT80E3 | 40G | QSFP+ | BASE-SR4 BiDi | N/A | AMC Optics | QSFP40GSBDAMC | No | "3.8.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 40G | QSFP+ | BASE-SR4 BiDi | N/A | AMC Optics | QSFP40GSBDAMC | No | "3.8.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 40G | QSFP+ | BASE-SR4 BiDi | N/A | AMC Optics | QSFP40GSBDAMC | No | "3.8.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes | No |
NT40E2-1 | 40G | QSFP+ | BASE-SR4 BiDi | N/A | AMC Optics | QSFP40GSBDRXAMC | No | "3.8.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | Yes | No | No | No | na | na | No |
NT80E3 | 40G | QSFP+ | BASE-SR4 BiDi | N/A | AMC Optics | QSFP40GSBDRXAMC | No | "3.8.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | Yes | No | No | No | na | na | No |
NT200A01 | 40G | QSFP+ | BASE-SR4 BiDi | N/A | AMC Optics | QSFP40GSBDRXAMC | No | "3.8.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | Yes | No | No | No | na | na | No |
NT200A02 | 40G | QSFP+ | BASE-SR4 BiDi | N/A | AMC Optics | QSFP40GSBDRXAMC | No | "3.8.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | Yes | No | No | No | na | na | No |
NT40E2-1 | 40G | QSFP+ | BASE-SR4 BiDi | N/A | Cisco | QSFP-40G-BD-RX | No | "3.8.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | Yes | Yes | Yes | Yes | na | na | No |
NT80E3 | 40G | QSFP+ | BASE-SR4 BiDi | N/A | Cisco | QSFP-40G-BD-RX | No | "3.8.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | Yes | Yes | Yes | Yes | na | na | No |
NT200A01 | 40G | QSFP+ | BASE-SR4 BiDi | N/A | Cisco | QSFP-40G-BD-RX | No | "3.8.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | Yes | Yes | Yes | Yes | na | na | No |
NT200A02 | 40G | QSFP+ | BASE-SR4 BiDi | N/A | Cisco | QSFP-40G-BD-RX | No | "3.8.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | Yes | Yes | Yes | Yes | na | na | No |
NT40E2-1 | 40G | QSFP+ | BASE-SR4 BiDi | N/A | ProLabs | QSFP-40G-BD-RX-C | No | "3.8.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | Yes | Yes | Yes | Yes | na | na | No |
NT80E3 | 40G | QSFP+ | BASE-SR4 BiDi | N/A | ProLabs | QSFP-40G-BD-RX-C | No | "3.8.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | Yes | Yes | Yes | Yes | na | na | No |
NT200A01 | 40G | QSFP+ | BASE-SR4 BiDi | N/A | ProLabs | QSFP-40G-BD-RX-C | No | "3.8.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | Yes | Yes | Yes | Yes | na | na | No |
NT200A02 | 40G | QSFP+ | BASE-SR4 BiDi | N/A | ProLabs | QSFP-40G-BD-RX-C | No | "3.8.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | Yes | Yes | Yes | Yes | na | na | No |
NT40E2-1 | 40G | QSFP+ | BASE-SR4 BiDi | N/A | Integra | QSFP-40G-SR-BD-IO | No | "3.8.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | Yes | No | No | No | No | na | No |
NT80E3 | 40G | QSFP+ | BASE-SR4 BiDi | N/A | Integra | QSFP-40G-SR-BD-IO | No | "3.8.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | Yes | No | No | No | No | na | No |
NT200A01 | 40G | QSFP+ | BASE-SR4 BiDi | N/A | Integra | QSFP-40G-SR-BD-IO | No | "3.8.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | Yes | No | No | No | No | na | No |
NT200A02 | 40G | QSFP+ | BASE-SR4 BiDi | N/A | Integra | QSFP-40G-SR-BD-IO | No | "3.8.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | Yes | No | No | No | No | na | No |
NT40E2-1 | 40G | QSFP+ | BASE-SWDM4 | N/A | Finisar | FTL4S1QE2C | No | "3.8.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT80E3 | 40G | QSFP+ | BASE-SWDM4 | N/A | Finisar | FTL4S1QE2C | No | "3.8.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 40G | QSFP+ | BASE-SWDM4 | N/A | Finisar | FTL4S1QE2C | No | "3.8.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 40G | QSFP+ | BASE-SWDM4 | N/A | Finisar | FTL4S1QE2C | No | "3.8.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT40E2-1 | 40G | QSFP+ | BASE-CR4 | N/A | Mellanox | MC2210126-005 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 5.0 m | 26 AWG | No | N/A | N/A | N/A | N/A | No | No |
NT80E3 | 40G | QSFP+ | BASE-CR4 | N/A | Mellanox | MC2210126-005 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 5.0 m | 26 AWG | No | N/A | N/A | N/A | N/A | No | No |
NT200B01 | 40G | QSFP+ | BASE-CR4 | N/A | Mellanox | MC2210126-005 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 5.0 m | 26 AWG | No | N/A | N/A | N/A | N/A | No | No |
NT200A01 | 40G | QSFP+ | BASE-CR4 | N/A | Mellanox | MC2210126-005 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 5.0 m | 26 AWG | No | N/A | N/A | N/A | N/A | No | No |
NT200A02 | 40G | QSFP+ | BASE-CR4 | N/A | Mellanox | MC2210126-005 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 5.0 m | 26 AWG | No | N/A | N/A | N/A | N/A | No | No |
NT100E3 | 100G | CFP4 | BASE-LR4 | 802-0074-01-10 | Sumitomo | SFF1400L4LNGG01B | Yes | "2.8.1" | 4 | 0 to 70 | N/A | Bail | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT100E3 | 100G | CFP4 | BASE-LR4 | 802-0074-01-10 | Sumitomo | SFF1400L4LNNP01B | No | "2.8.1" | 4 | 0 to 70 | N/A | Bail | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT100E3 | 100G | CFP4 | BASE-LR4 | 802-0074-01-10 | Sumitomo | SFF1401L4LNNP01B | No | "2.8.1" | 4 | 0 to 70 | N/A | Bail | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT100E3 | 100G | CFP4 | BASE-LR4 | 802-0074-01-10 | Lumentum | JC4-10LR4AA1 | No | "2.8.1" | 4 | 0 to 70 | N/A | Bail | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT100E3 | 100G | CFP4 | BASE-LR4 | 802-0074-01-10 | Finisar | FTLC1141RDNL | No | "2.8.1" | 4 | 0 to 70 | N/A | Bail | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT100E3 | 100G | CFP4 | BASE-SR4 | 802-0073-01-10 | Finisar | FTLC9141RENM | No | "2.8.1" | 4 | 0 to 70 | N/A | Bail | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT200B01 | 100G | QSFP28 | BASE-DR1 | N/A | Innolight | TR-ZC13H-N00 | No | "3.25.6" | 6 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 100G | QSFP28 | BASE-DR1 | N/A | Innolight | TR-ZC13H-N00 | No | "3.25.6" | 6 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 100G | QSFP28 | BASE-DR1 | N/A | Innolight | TR-ZC13H-N00 | No | "3.25.6" | 6 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT400D11 | 100G | QSFP28 | BASE-DR1 | N/A | Innolight | TR-ZC13H-N00 | No | "3.25.6" | 6 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200B01 | 100G | QSFP28 | BASE-DR1 | N/A | Finisar | FTLC4352RHPL | No | "3.25.6" | 6 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 100G | QSFP28 | BASE-DR1 | N/A | Finisar | FTLC4352RHPL | No | "3.25.6" | 6 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 100G | QSFP28 | BASE-DR1 | N/A | Finisar | FTLC4352RHPL | No | "3.25.6" | 6 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT400D11 | 100G | QSFP28 | BASE-DR1 | N/A | Finisar | FTLC4352RHPL | No | "3.25.6" | 6 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200B01 | 100G | QSFP28 | BASE-DR1 | N/A | AMC Optics | QSFP100GDR1AMC | No | "3.25.6" | 6 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 100G | QSFP28 | BASE-DR1 | N/A | AMC Optics | QSFP100GDR1AMC | No | "3.25.6" | 6 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 100G | QSFP28 | BASE-DR1 | N/A | AMC Optics | QSFP100GDR1AMC | No | "3.25.6" | 6 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT400D11 | 100G | QSFP28 | BASE-DR1 | N/A | AMC Optics | QSFP100GDR1AMC | No | "3.25.6" | 6 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200B01 | 100G | QSFP28 | BASE-FR1 | N/A | Innolight | TR-ZC13T-N00 | No | "3.25.6" | 6 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 100G | QSFP28 | BASE-FR1 | N/A | Innolight | TR-ZC13T-N00 | No | "3.25.6" | 6 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 100G | QSFP28 | BASE-FR1 | N/A | Innolight | TR-ZC13T-N00 | No | "3.25.6" | 6 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT400D11 | 100G | QSFP28 | BASE-FR1 | N/A | Innolight | TR-ZC13T-N00 | No | "3.25.6" | 6 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200B01 | 100G | QSFP28 | BASE-FR1 | N/A | Finisar | FTLC4352RJPL | No | "3.25.6" | 6 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 100G | QSFP28 | BASE-FR1 | N/A | Finisar | FTLC4352RJPL | No | "3.25.6" | 6 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 100G | QSFP28 | BASE-FR1 | N/A | Finisar | FTLC4352RJPL | No | "3.25.6" | 6 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT400D11 | 100G | QSFP28 | BASE-FR1 | N/A | Finisar | FTLC4352RJPL | No | "3.25.6" | 6 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200B01 | 100G | QSFP28 | BASE-FR1 | N/A | AMC Optics | QSFP100GFR1AMC | No | "3.25.6" | 6 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 100G | QSFP28 | BASE-FR1 | N/A | AMC Optics | QSFP100GFR1AMC | No | "3.25.6" | 6 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 100G | QSFP28 | BASE-FR1 | N/A | AMC Optics | QSFP100GFR1AMC | No | "3.25.6" | 6 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT400D11 | 100G | QSFP28 | BASE-FR1 | N/A | AMC Optics | QSFP100GFR1AMC | No | "3.25.6" | 6 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200B01 | 100G | QSFP28 | BASE-LR1 | N/A | Innolight | TR-ZC13L-N00 | No | "3.25.6" | 6 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 100G | QSFP28 | BASE-LR1 | N/A | Innolight | TR-ZC13L-N00 | No | "3.25.6" | 6 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 100G | QSFP28 | BASE-LR1 | N/A | Innolight | TR-ZC13L-N00 | No | "3.25.6" | 6 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT400D11 | 100G | QSFP28 | BASE-LR1 | N/A | Innolight | TR-ZC13L-N00 | No | "3.25.6" | 6 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200B01 | 100G | QSFP28 | BASE-LR1 | N/A | Finisar | FTLC4352RKPL | No | "3.25.6" | 6 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 100G | QSFP28 | BASE-LR1 | N/A | Finisar | FTLC4352RKPL | No | "3.25.6" | 6 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 100G | QSFP28 | BASE-LR1 | N/A | Finisar | FTLC4352RKPL | No | "3.25.6" | 6 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT400D11 | 100G | QSFP28 | BASE-LR1 | N/A | Finisar | FTLC4352RKPL | No | "3.25.6" | 6 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200B01 | 100G | QSFP28 | BASE-LR1 | N/A | AMC Optics | QSFP100GLR1AMC | No | "3.25.6" | 6 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 100G | QSFP28 | BASE-LR1 | N/A | AMC Optics | QSFP100GLR1AMC | No | "3.25.6" | 6 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 100G | QSFP28 | BASE-LR1 | N/A | AMC Optics | QSFP100GLR1AMC | No | "3.25.6" | 6 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT400D11 | 100G | QSFP28 | BASE-LR1 | N/A | AMC Optics | QSFP100GLR1AMC | No | "3.25.6" | 6 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200B01 | 100G | QSFP28 | BASE-SR4 | 802-0081-01-10 | FIT | AFBR-89CDDZ | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A01 | 100G | QSFP28 | BASE-SR4 | 802-0081-01-10 | FIT | AFBR-89CDDZ | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 100G | QSFP28 | BASE-SR4 | 802-0081-01-10 | FIT | AFBR-89CDDZ | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT400D11 | 100G | QSFP28 | BASE-SR4 | 802-0081-01-10 | FIT | AFBR-89CDDZ | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT200B01 | 4x25G breakout | QSFP28 | BASE-SR4 | 802-0081-01-10 | FIT | AFBR-89CDDZ | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A01 | 4x25G breakout | QSFP28 | BASE-SR4 | 802-0081-01-10 | FIT | AFBR-89CDDZ | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 4x25G breakout | QSFP28 | BASE-SR4 | 802-0081-01-10 | FIT | AFBR-89CDDZ | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT400D11 | 4x25G breakout | QSFP28 | BASE-SR4 | 802-0081-01-10 | FIT | AFBR-89CDDZ | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT200B01 | 100G | QSFP28 | BASE-SR4 | 802-0081-01-10 | Finisar | FTLC9551REPM | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A01 | 100G | QSFP28 | BASE-SR4 | 802-0081-01-10 | Finisar | FTLC9551REPM | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 100G | QSFP28 | BASE-SR4 | 802-0081-01-10 | Finisar | FTLC9551REPM | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT400D11 | 100G | QSFP28 | BASE-SR4 | 802-0081-01-10 | Finisar | FTLC9551REPM | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT200B01 | 4x25G breakout | QSFP28 | BASE-SR4 | 802-0081-01-10 | Finisar | FTLC9551REPM | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A01 | 4x25G breakout | QSFP28 | BASE-SR4 | 802-0081-01-10 | Finisar | FTLC9551REPM | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 4x25G breakout | QSFP28 | BASE-SR4 | 802-0081-01-10 | Finisar | FTLC9551REPM | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT400D11 | 4x25G breakout | QSFP28 | BASE-SR4 | 802-0081-01-10 | Finisar | FTLC9551REPM | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT200B01 | 100G | QSFP28 | BASE-SR4 | 802-0081-01-10 | Finisar | FTLC9558REPM | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A01 | 100G | QSFP28 | BASE-SR4 | 802-0081-01-10 | Finisar | FTLC9558REPM | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 100G | QSFP28 | BASE-SR4 | 802-0081-01-10 | Finisar | FTLC9558REPM | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT400D11 | 100G | QSFP28 | BASE-SR4 | 802-0081-01-10 | Finisar | FTLC9558REPM | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT200B01 | 4x25G breakout | QSFP28 | BASE-SR4 | 802-0081-01-10 | Finisar | FTLC9558REPM | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A01 | 4x25G breakout | QSFP28 | BASE-SR4 | 802-0081-01-10 | Finisar | FTLC9558REPM | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 4x25G breakout | QSFP28 | BASE-SR4 | 802-0081-01-10 | Finisar | FTLC9558REPM | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT400D11 | 4x25G breakout | QSFP28 | BASE-SR4 | 802-0081-01-10 | Finisar | FTLC9558REPM | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT200B01 | 100G | QSFP28 | BASE-SR4 | N/A | Innolight | TR-FC85S-N00 | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 100G | QSFP28 | BASE-SR4 | N/A | Innolight | TR-FC85S-N00 | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 100G | QSFP28 | BASE-SR4 | N/A | Innolight | TR-FC85S-N00 | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT400D11 | 100G | QSFP28 | BASE-SR4 | N/A | Innolight | TR-FC85S-N00 | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200B01 | 4x25G breakout | QSFP28 | BASE-SR4 | N/A | Innolight | TR-FC85S-N00 | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 4x25G breakout | QSFP28 | BASE-SR4 | N/A | Innolight | TR-FC85S-N00 | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 4x25G breakout | QSFP28 | BASE-SR4 | N/A | Innolight | TR-FC85S-N00 | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT400D11 | 4x25G breakout | QSFP28 | BASE-SR4 | N/A | Innolight | TR-FC85S-N00 | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200B01 | 100G | QSFP28 | BASE-SR4 | N/A | Innolight | TR-FC85S-NVS | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 100G | QSFP28 | BASE-SR4 | N/A | Innolight | TR-FC85S-NVS | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 100G | QSFP28 | BASE-SR4 | N/A | Innolight | TR-FC85S-NVS | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT400D11 | 100G | QSFP28 | BASE-SR4 | N/A | Innolight | TR-FC85S-NVS | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200B01 | 4x25G breakout | QSFP28 | BASE-SR4 | N/A | Innolight | TR-FC85S-NVS | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 4x25G breakout | QSFP28 | BASE-SR4 | N/A | Innolight | TR-FC85S-NVS | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 4x25G breakout | QSFP28 | BASE-SR4 | N/A | Innolight | TR-FC85S-NVS | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT400D11 | 4x25G breakout | QSFP28 | BASE-SR4 | N/A | Innolight | TR-FC85S-NVS | No | "3.3.0" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200B01 | 100G | QSFP28 | BASE-LR4 | 802-0082-01-10 | Sumitomo | SQF1001L4LNGG01B | Yes | "3.3.0" | 5 | 0 to 70 | N/A | Bail | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 100G | QSFP28 | BASE-LR4 | 802-0082-01-10 | Sumitomo | SQF1001L4LNGG01B | Yes | "3.3.0" | 5 | 0 to 70 | N/A | Bail | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 100G | QSFP28 | BASE-LR4 | 802-0082-01-10 | Sumitomo | SQF1001L4LNGG01B | Yes | "3.3.0" | 5 | 0 to 70 | N/A | Bail | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT400D11 | 100G | QSFP28 | BASE-LR4 | 802-0082-01-10 | Sumitomo | SQF1001L4LNGG01B | Yes | "3.3.0" | 5 | 0 to 70 | N/A | Bail | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200B01 | 100G | QSFP28 | BASE-LR4 | 802-0082-01-10 | Sumitomo | SQF1002L4LNGG01B | Yes | "3.3.0" | 5 | 0 to 70 | N/A | Bail | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A01 | 100G | QSFP28 | BASE-LR4 | 802-0082-01-10 | Sumitomo | SQF1002L4LNGG01B | Yes | "3.3.0" | 5 | 0 to 70 | N/A | Bail | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 100G | QSFP28 | BASE-LR4 | 802-0082-01-10 | Sumitomo | SQF1002L4LNGG01B | Yes | "3.3.0" | 5 | 0 to 70 | N/A | Bail | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT400D11 | 100G | QSFP28 | BASE-LR4 | 802-0082-01-10 | Sumitomo | SQF1002L4LNGG01B | Yes | "3.3.0" | 5 | 0 to 70 | N/A | Bail | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT200B01 | 100G | QSFP28 | BASE-LR4 | 802-0082-01-10 | Fujitsu | FIM37700/171 | Yes | "3.3.0" | 5 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A01 | 100G | QSFP28 | BASE-LR4 | 802-0082-01-10 | Fujitsu | FIM37700/171 | Yes | "3.3.0" | 5 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 100G | QSFP28 | BASE-LR4 | 802-0082-01-10 | Fujitsu | FIM37700/171 | Yes | "3.3.0" | 5 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT400D11 | 100G | QSFP28 | BASE-LR4 | 802-0082-01-10 | Fujitsu | FIM37700/171 | Yes | "3.3.0" | 5 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT200B01 | 100G | QSFP28 | BASE-LR4 | 802-0082-01-10 | Fujitsu | FIM37700/172 | Yes | "3.3.0" | 5 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A01 | 100G | QSFP28 | BASE-LR4 | 802-0082-01-10 | Fujitsu | FIM37700/172 | Yes | "3.3.0" | 5 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 100G | QSFP28 | BASE-LR4 | 802-0082-01-10 | Fujitsu | FIM37700/172 | Yes | "3.3.0" | 5 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT400D11 | 100G | QSFP28 | BASE-LR4 | 802-0082-01-10 | Fujitsu | FIM37700/172 | Yes | "3.3.0" | 5 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT200B01 | 100G | QSFP28 | BASE-LR4 | 802-0082-01-10 | Innolight | TR-FC13R-N00 | No | "3.3.0" | 5 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A01 | 100G | QSFP28 | BASE-LR4 | 802-0082-01-10 | Innolight | TR-FC13R-N00 | No | "3.3.0" | 5 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 100G | QSFP28 | BASE-LR4 | 802-0082-01-10 | Innolight | TR-FC13R-N00 | No | "3.3.0" | 5 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT400D11 | 100G | QSFP28 | BASE-LR4 | 802-0082-01-10 | Innolight | TR-FC13R-N00 | No | "3.3.0" | 5 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT200B01 | 100G | QSFP28 | BASE-LR4 | N/A | Innolight | TR-FC13L-NVS | No | "3.3.0" | 5 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 100G | QSFP28 | BASE-LR4 | N/A | Innolight | TR-FC13L-NVS | No | "3.3.0" | 5 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 100G | QSFP28 | BASE-LR4 | N/A | Innolight | TR-FC13L-NVS | No | "3.3.0" | 5 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT400D11 | 100G | QSFP28 | BASE-LR4 | N/A | Innolight | TR-FC13L-NVS | No | "3.3.0" | 5 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200B01 | 100G | QSFP28 | BASE-LR4 | 802-0082-01-10 | Finisar | FTLC1156RDPL | No | "3.3.0" | 5 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A01 | 100G | QSFP28 | BASE-LR4 | 802-0082-01-10 | Finisar | FTLC1156RDPL | No | "3.3.0" | 5 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 100G | QSFP28 | BASE-LR4 | 802-0082-01-10 | Finisar | FTLC1156RDPL | No | "3.3.0" | 5 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT400D11 | 100G | QSFP28 | BASE-LR4 | 802-0082-01-10 | Finisar | FTLC1156RDPL | No | "3.3.0" | 5 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT200B01 | 100G | QSFP28 | BASE-LR4 | 802-0082-01-10 | Intel | SPTSBP4LLCDF | No | "3.3.0" | 5 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A01 | 100G | QSFP28 | BASE-LR4 | 802-0082-01-10 | Intel | SPTSBP4LLCDF | No | "3.3.0" | 5 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT200A02 | 100G | QSFP28 | BASE-LR4 | 802-0082-01-10 | Intel | SPTSBP4LLCDF | No | "3.3.0" | 5 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT400D11 | 100G | QSFP28 | BASE-LR4 | 802-0082-01-10 | Intel | SPTSBP4LLCDF | No | "3.3.0" | 5 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | Yes |
NT200B01 | 100G | QSFP28 | BASE-PSM4 | 802-0096-01-10 | Innolight | TR-VC13T-N00 | No | "3.21.4" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 100G | QSFP28 | BASE-PSM4 | 802-0096-01-10 | Innolight | TR-VC13T-N00 | No | "3.21.4" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 100G | QSFP28 | BASE-PSM4 | 802-0096-01-10 | Innolight | TR-VC13T-N00 | No | "3.21.4" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT400D11 | 100G | QSFP28 | BASE-PSM4 | 802-0096-01-10 | Innolight | TR-VC13T-N00 | No | "3.21.4" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200B01 | 4x25G breakout | QSFP28 | BASE-PSM4 | 802-0096-01-10 | Innolight | TR-VC13T-N00 | No | "3.21.4" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 4x25G breakout | QSFP28 | BASE-PSM4 | 802-0096-01-10 | Innolight | TR-VC13T-N00 | No | "3.21.4" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 4x25G breakout | QSFP28 | BASE-PSM4 | 802-0096-01-10 | Innolight | TR-VC13T-N00 | No | "3.21.4" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT400D11 | 4x25G breakout | QSFP28 | BASE-PSM4 | 802-0096-01-10 | Innolight | TR-VC13T-N00 | No | "3.21.4" | 4 | 0 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200B01 | 100G | QSFP28 | BASE-PSM4 | N/A | AMC Optics | QSFP28PSM4AMC | No | "3.21.4" | 4 | -5 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 100G | QSFP28 | BASE-PSM4 | N/A | AMC Optics | QSFP28PSM4AMC | No | "3.21.4" | 4 | -5 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 100G | QSFP28 | BASE-PSM4 | N/A | AMC Optics | QSFP28PSM4AMC | No | "3.21.4" | 4 | -5 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT400D11 | 100G | QSFP28 | BASE-PSM4 | N/A | AMC Optics | QSFP28PSM4AMC | No | "3.21.4" | 4 | -5 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200B01 | 4x25G breakout | QSFP28 | BASE-PSM4 | N/A | AMC Optics | QSFP28PSM4AMC | No | "3.21.4" | 4 | -5 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 4x25G breakout | QSFP28 | BASE-PSM4 | N/A | AMC Optics | QSFP28PSM4AMC | No | "3.21.4" | 4 | -5 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 4x25G breakout | QSFP28 | BASE-PSM4 | N/A | AMC Optics | QSFP28PSM4AMC | No | "3.21.4" | 4 | -5 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT400D11 | 4x25G breakout | QSFP28 | BASE-PSM4 | N/A | AMC Optics | QSFP28PSM4AMC | No | "3.21.4" | 4 | -5 to 70 | N/A | Strap | MPO | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200B01 | 100G | QSFP28 | BASE-CWDM4 | N/A | Innolight | TR-FC13T-N00 | No | "3.18.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 100G | QSFP28 | BASE-CWDM4 | N/A | Innolight | TR-FC13T-N00 | No | "3.18.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 100G | QSFP28 | BASE-CWDM4 | N/A | Innolight | TR-FC13T-N00 | No | "3.18.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT400D11 | 100G | QSFP28 | BASE-CWDM4 | N/A | Innolight | TR-FC13T-N00 | No | "3.18.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200B01 | 100G | QSFP28 | BASE-CWDM4 | N/A | Finisar | FTLC1155RGPL | No | "3.18.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 100G | QSFP28 | BASE-CWDM4 | N/A | Finisar | FTLC1155RGPL | No | "3.18.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 100G | QSFP28 | BASE-CWDM4 | N/A | Finisar | FTLC1155RGPL | No | "3.18.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT400D11 | 100G | QSFP28 | BASE-CWDM4 | N/A | Finisar | FTLC1155RGPL | No | "3.18.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200B01 | 100G | QSFP28 | BASE-CWDM4 | N/A | Finisar | FTLC1157RGPL | No | "3.18.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 100G | QSFP28 | BASE-CWDM4 | N/A | Finisar | FTLC1157RGPL | No | "3.18.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 100G | QSFP28 | BASE-CWDM4 | N/A | Finisar | FTLC1157RGPL | No | "3.18.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT400D11 | 100G | QSFP28 | BASE-CWDM4 | N/A | Finisar | FTLC1157RGPL | No | "3.18.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200B01 | 100G | QSFP28 | BASE-CWDM4 | N/A | AMC Optics | QSFP28CWDM4AMC | No | "3.18.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 100G | QSFP28 | BASE-CWDM4 | N/A | AMC Optics | QSFP28CWDM4AMC | No | "3.18.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 100G | QSFP28 | BASE-CWDM4 | N/A | AMC Optics | QSFP28CWDM4AMC | No | "3.18.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT400D11 | 100G | QSFP28 | BASE-CWDM4 | N/A | AMC Optics | QSFP28CWDM4AMC | No | "3.18.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200B01 | 100G | QSFP28 | BASE-SWDM4 | N/A | Finisar | FTLC9152RGPL | No | "3.18.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 100G | QSFP28 | BASE-SWDM4 | N/A | Finisar | FTLC9152RGPL | No | "3.18.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 100G | QSFP28 | BASE-SWDM4 | N/A | Finisar | FTLC9152RGPL | No | "3.18.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT400D11 | 100G | QSFP28 | BASE-SWDM4 | N/A | Finisar | FTLC9152RGPL | No | "3.18.0" | 4 | 0 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200B01 | 40/100G | QSFP28 | BASE-SR4 BiDi | N/A | FIT | AFBR-89BDDZ | No | "3.20.4" | 4 | 10 to 60 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 40/100G | QSFP28 | BASE-SR4 BiDi | N/A | FIT | AFBR-89BDDZ | No | "3.20.4" | 4 | 10 to 60 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 40/100G | QSFP28 | BASE-SR4 BiDi | N/A | FIT | AFBR-89BDDZ | No | "3.20.4" | 4 | 10 to 60 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT400D11 | 40/100G | QSFP28 | BASE-SR4 BiDi | N/A | FIT | AFBR-89BDDZ | No | "3.20.4" | 4 | 10 to 60 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200B01 | 40/100G | QSFP28 | BASE-SR4 BiDi | N/A | Cisco | QSFP-40/100-SRBD | No | "3.20.4" | 4 | 10 to 60 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 40/100G | QSFP28 | BASE-SR4 BiDi | N/A | Cisco | QSFP-40/100-SRBD | No | "3.20.4" | 4 | 10 to 60 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 40/100G | QSFP28 | BASE-SR4 BiDi | N/A | Cisco | QSFP-40/100-SRBD | No | "3.20.4" | 4 | 10 to 60 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT400D11 | 40/100G | QSFP28 | BASE-SR4 BiDi | N/A | Cisco | QSFP-40/100-SRBD | No | "3.20.4" | 4 | 10 to 60 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200B01 | 100G | QSFP28 | BASE-SR4 BiDi | N/A | FIT | AFBR-89BRDZ | No | "3.20.4" | 4 | 10 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A01 | 100G | QSFP28 | BASE-SR4 BiDi | N/A | FIT | AFBR-89BRDZ | No | "3.20.4" | 4 | 10 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT200A02 | 100G | QSFP28 | BASE-SR4 BiDi | N/A | FIT | AFBR-89BRDZ | No | "3.20.4" | 4 | 10 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT400D11 | 100G | QSFP28 | BASE-SR4 BiDi | N/A | FIT | AFBR-89BRDZ | No | "3.20.4" | 4 | 10 to 70 | N/A | Strap | LC | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Yes | No |
NT40E2-1 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE30N 0.5 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 0.5 m | 30 AWG | Yes | N/A | N/A | N/A | N/A | No | Yes |
NT80E3 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE30N 0.5 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 0.5 m | 30 AWG | Yes | N/A | N/A | N/A | N/A | No | Yes |
NT200B01 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE30N 0.5 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 0.5 m | 30 AWG | Yes | N/A | N/A | N/A | N/A | No | Yes |
NT200A01 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE30N 0.5 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 0.5 m | 30 AWG | Yes | N/A | N/A | N/A | N/A | No | Yes |
NT200A02 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE30N 0.5 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 0.5 m | 30 AWG | Yes | N/A | N/A | N/A | N/A | No | Yes |
NT400D11 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE30N 0.5 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 0.5 m | 30 AWG | Yes | N/A | N/A | N/A | N/A | No | Yes |
NT40E2-1 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE30N 1 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 1.0 m | 30 AWG | Yes | N/A | N/A | N/A | N/A | No | Yes |
NT80E3 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE30N 1 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 1.0 m | 30 AWG | Yes | N/A | N/A | N/A | N/A | No | Yes |
NT200B01 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE30N 1 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 1.0 m | 30 AWG | Yes | N/A | N/A | N/A | N/A | No | Yes |
NT200A01 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE30N 1 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 1.0 m | 30 AWG | Yes | N/A | N/A | N/A | N/A | No | Yes |
NT200A02 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE30N 1 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 1.0 m | 30 AWG | Yes | N/A | N/A | N/A | N/A | No | Yes |
NT400D11 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE30N 1 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 1.0 m | 30 AWG | Yes | N/A | N/A | N/A | N/A | No | Yes |
NT40E2-1 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE30N 1.5 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 1.5 m | 30 AWG | Yes | N/A | N/A | N/A | N/A | No | Yes |
NT80E3 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE30N 1.5 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 1.5 m | 30 AWG | Yes | N/A | N/A | N/A | N/A | No | Yes |
NT200B01 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE30N 1.5 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 1.5 m | 30 AWG | Yes | N/A | N/A | N/A | N/A | No | Yes |
NT200A01 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE30N 1.5 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 1.5 m | 30 AWG | Yes | N/A | N/A | N/A | N/A | No | Yes |
NT200A02 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE30N 1.5 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 1.5 m | 30 AWG | Yes | N/A | N/A | N/A | N/A | No | Yes |
NT400D11 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE30N 1.5 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 1.5 m | 30 AWG | Yes | N/A | N/A | N/A | N/A | No | Yes |
NT40E2-1 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE30N 2 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 2.0 m | 30 AWG | Yes | N/A | N/A | N/A | N/A | No | Yes |
NT80E3 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE30N 2 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 2.0 m | 30 AWG | Yes | N/A | N/A | N/A | N/A | No | Yes |
NT200B01 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE30N 2 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 2.0 m | 30 AWG | Yes | N/A | N/A | N/A | N/A | No | Yes |
NT200A01 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE30N 2 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 2.0 m | 30 AWG | Yes | N/A | N/A | N/A | N/A | No | Yes |
NT200A02 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE30N 2 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 2.0 m | 30 AWG | Yes | N/A | N/A | N/A | N/A | No | Yes |
NT400D11 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE30N 2 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 2.0 m | 30 AWG | Yes | N/A | N/A | N/A | N/A | No | Yes |
NT40E2-1 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE30L 2.5 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 2.5 m | 30 AWG | Yes | N/A | N/A | N/A | N/A | No | Yes |
NT80E3 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE30L 2.5 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 2.5 m | 30 AWG | Yes | N/A | N/A | N/A | N/A | No | Yes |
NT200B01 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE30L 2.5 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 2.5 m | 30 AWG | Yes | N/A | N/A | N/A | N/A | No | Yes |
NT200A01 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE30L 2.5 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 2.5 m | 30 AWG | Yes | N/A | N/A | N/A | N/A | No | Yes |
NT200A02 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE30L 2.5 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 2.5 m | 30 AWG | Yes | N/A | N/A | N/A | N/A | No | Yes |
NT400D11 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE30L 2.5 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 2.5 m | 30 AWG | Yes | N/A | N/A | N/A | N/A | No | Yes |
NT40E2-1 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE30L 3 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 3.0 m | 30 AWG | Yes | N/A | N/A | N/A | N/A | No | Yes |
NT80E3 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE30L 3 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 3.0 m | 30 AWG | Yes | N/A | N/A | N/A | N/A | No | Yes |
NT200B01 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE30L 3 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 3.0 m | 30 AWG | Yes | N/A | N/A | N/A | N/A | No | Yes |
NT200A01 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE30L 3 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 3.0 m | 30 AWG | Yes | N/A | N/A | N/A | N/A | No | Yes |
NT200A02 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE30L 3 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 3.0 m | 30 AWG | Yes | N/A | N/A | N/A | N/A | No | Yes |
NT400D11 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE30L 3 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 3.0 m | 30 AWG | Yes | N/A | N/A | N/A | N/A | No | Yes |
NT40E2-1 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE26L 5 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 5.0 m | 26 AWG | Yes | N/A | N/A | N/A | N/A | No | No |
NT80E3 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE26L 5 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 5.0 m | 26 AWG | Yes | N/A | N/A | N/A | N/A | No | No |
NT200B01 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE26L 5 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 5.0 m | 26 AWG | Yes | N/A | N/A | N/A | N/A | No | No |
NT200A01 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE26L 5 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 5.0 m | 26 AWG | Yes | N/A | N/A | N/A | N/A | No | No |
NT200A02 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE26L 5 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 5.0 m | 26 AWG | Yes | N/A | N/A | N/A | N/A | No | No |
NT400D11 | 40/100G | QSFP28 | BASE-CR4 | N/A | Mellanox | MCP1600-C00AE26L 5 | No | "3.8.0" | I | 0 to 70 | N/A | Strap | N/A | 5.0 m | 26 AWG | Yes | N/A | N/A | N/A | N/A | No | No |
SmartNIC | Link Speed Gbit/s | Form Factor | Link Type | Manufacturer |
(1) Power Class is not defined for SFP modules. Compliance to the standard (MSA INF-8074) allows up to 1 W of power consumption. The value in the table is “I” if power consumption is 1 W or less, and “II” if power consumption is more than 1 W.
Legend:
N/A – Not available
Unkn – Unknown
P/W – Password
Notes:
For further details please see DN-0390 Network Accelerators Qualification Criteria for Pluggable Transceiver Modules.
Certification only applies to the individual pluggable modules as per the manufacturer’s data sheet and is the sole responsibility of the manufacturer. Napatech is not responsible for changes. For pluggable modules homologated with Napatech accelerators please see Certificates for Regulatory Compliance, Safety, Environment on the Napatech Support Portal.
Disclaimer:
This document is intended for informational purposes only. Any information herein is believed to be reliable. However, Napatech assumes no responsibility for the accuracy of the information. Napatech reserves the right to change the document and the products described without notice. Napatech and the authors disclaim any and all liabilities. Napatech is a trademark used under license by Napatech A/S. All other logos, trademarks and service marks are the property of the respective third parties. Copyright © Napatech A/S 2021. All rights reserved.